83138G
1.REMOVE COMBINATION METER GLASS
Remove the 9 bushes.
Disengage the 12 claws to remove the combination meter glass.
83821A
2.REMOVE NO. 1 COMBINATION METER COVER
Remove the 2 screws.
Disengage the 10 claws to remove the No. 1 combination meter cover.
83133
3.REMOVE NO. 1 COMBINATION METER PLATE
Disengage the 3 guides and remove the No. 1 combination meter plate.
83132D
4.REMOVE NO. 2 COMBINATION METER CASE
Remove the screw.
Disengage the 2 guides and remove the No. 2 combination meter case.
Remove the 2 screws.
|
Remove in this Direction |
Disengage the 2 guides and disconnect the connector to remove the No. 2 combination meter case with combination meter multi-display as shown in the illustration.
Make sure to pull the connector straight up when disconnecting it as it is easily damaged.
Do not apply excessive force to the connector.
|
Remove in this Direction |
Disengage the 2 guides to remove the combination meter multi-display from the No. 2 combination meter case as shown in the illustration.
83247B
5.REMOVE NO. 2 METER CIRCUIT PLATE
Remove the 4 screws.
|
Remove in this Direction |
Disengage the 4 guides to remove the No. 2 meter circuit plate as shown in the illustration.
83247
6.REMOVE METER CIRCUIT PLATE
Disengage the 4 claws and 4 guides.
|
Remove in this Direction |
Disengage the 4 claws and raise the 2 holders.
Make sure not to rotate the holder 90° or more, or it may be damaged.
Disconnect each connector to remove the TFT display from the meter circuit plate as shown in the illustration.