Home › Vehicle Interior › DOOR LOCK › FRONT DOOR LOCK
RM3210E _58 Vehicle Interior _047513 DOOR LOCK _0237309 FRONT DOOR LOCK G

DOOR LOCK  FRONT DOOR LOCK  INSPECTION  


PROCEDURE

Hide 69040A 1.INSPECT FRONT DOOR LOCK WITH MOTOR ASSEMBLY LH (w/o Double Locking System)

a.
B429560C03
2.604,1.813 2.917,1.969 0.313,0.156 10 false *a 1.844,2.302 2.156,2.458 0.313,0.156 10 false *b 0.438,2.583 0.75,2.74 0.313,0.156 10 false *c
*a Unlock
*b Lock
*c Component without harness connected
(Front Door Lock with Motor Assembly LH)


Check the operation of the door lock motor.

i.

Apply auxiliary battery voltage and check the operation of the door lock motor.

OK:
Auxiliary Battery Connection Result
Auxiliary battery positive (+) → Terminal 4
Auxiliary battery negative (-) → Terminal 1
Locks
Auxiliary battery positive (+) → Terminal 1
Auxiliary battery negative (-) → Terminal 4
Unlocks


If the result is not as specified, replace the front door lock with motor assembly LH.



b.

Check the operation of the door unlock detection switch.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
7 - 8 Locked 10 kΩ or higher
7 - 8 Unlocked Below 1 Ω


If the result is not as specified, replace the front door lock with motor assembly LH.



c.
B429559C02
2.823,0.49 3.135,0.646 0.313,0.156 10 false *a 3.031,1.052 3.344,1.208 0.313,0.156 10 false *b 2.802,1.573 3.115,1.729 0.313,0.156 10 false *c 0.823,2.938 1.135,3.094 0.313,0.156 10 false *d
*a Lock
*b Neutral
*c Unlock
*d Component without harness connected
(Front Door Lock with Motor Assembly LH)


Check the operation of the door key lock and unlock switch. (for LHD)

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
9 - 7 Held to lock side Below 1 Ω
9 - 7 Neutral or held to unlock side 10 kΩ or higher
10 - 7 Held to unlock side Below 1 Ω
10 - 7 Neutral or held to lock side 10 kΩ or higher


If the result is not as specified, replace the front door lock with motor assembly LH.



Hide 69030A 2.INSPECT FRONT DOOR LOCK WITH MOTOR ASSEMBLY RH (w/o Double Locking System)

a.
B429558C03
0.729,1.792 1.042,1.948 0.313,0.156 10 false *a 1.458,2.271 1.771,2.427 0.313,0.156 10 false *b 0.604,2.885 0.917,3.042 0.313,0.156 10 false *c
*a Unlock
*b Lock
*c Component without harness connected
(Front Door Lock with Motor Assembly RH)


Check the operation of the door lock motor.

i.

Apply auxiliary battery voltage and check the operation of the door lock motor.

OK:
Auxiliary Battery Connection Result
Auxiliary battery positive (+) → Terminal 4
Auxiliary battery negative (-) → Terminal 1
Locks
Auxiliary battery positive (+) → Terminal 1
Auxiliary battery negative (-) → Terminal 4
Unlocks


If the result is not as specified, replace the front door lock with motor assembly RH.



b.

Check the operation of the door unlock detection switch.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
7 - 8 Locked 10 kΩ or higher
7 - 8 Unlocked Below 1 Ω


If the result is not as specified, replace the front door lock with motor assembly RH.



c.
B429557C02
0.49,0.5 0.802,0.656 0.313,0.156 10 false *a 0.281,1.042 0.594,1.198 0.313,0.156 10 false *b 0.458,1.573 0.771,1.729 0.313,0.156 10 false *c 0.49,2.76 0.802,2.917 0.313,0.156 10 false *d
*a Lock
*b Neutral
*c Unlock
*d Component without harness connected
(Front Door Lock with Motor Assembly RH)


Check the operation of the door key lock and unlock switch. (for RHD)

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
6 - 8 Held to lock side Below 1 Ω
6 - 8 Neutral or held to unlock side 10 kΩ or higher
5 - 8 Held to unlock side Below 1 Ω
5 - 8 Neutral or held to lock side 10 kΩ or higher


If the result is not as specified, replace the front door lock with motor assembly RH.



Hide 69030A 3.INSPECT FRONT DOOR LOCK WITH MOTOR ASSEMBLY LH (w/ Double Locking System)

a.
B228536C02
2.292,2.698 2.604,2.854 0.313,0.156 10 false *a 1.719,2.948 2.031,3.104 0.313,0.156 10 false *b 0.615,2.719 0.927,2.875 0.313,0.156 10 false *c
*a Unlock
*b Lock
*c Component without harness connected
(Front Door Lock with Motor Assembly LH)


Check the operation of the front door lock motor.

i.

Apply auxiliary battery voltage and check the operation of the front door lock motor and double lock motor.

OK:
Auxiliary Battery Connection Result
Auxiliary battery positive (+) → Terminal 4
Auxiliary battery negative (-) → Terminal 3
Locks
Auxiliary battery positive (+) → Terminal 3
Auxiliary battery negative (-) → Terminal 4
Unlocks
Auxiliary battery positive (+) → Terminal 2
Auxiliary battery negative (-) → Terminal 1
Sets
Auxiliary battery positive (+) → Terminal 1
Auxiliary battery negative (-) → Terminal 2
Unsets


HINT:
·

Move the door lock motor to the lock position and set the double locking system. Check that the doors cannot be unlocked by operating the control cable.

·

Move the door lock motor to the lock position and unset the double locking system. Check that the doors can be unlocked by operating the control cable.



If the result is not as specified, replace the front door lock with motor assembly LH.



b.

Check the operation of the door unlock detection switch and double lock position switch.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
8 - 7 Locked 10 kΩ or higher
8 - 7 Unlocked Below 1 Ω
6 - 5 Unset 10 kΩ or higher
6 - 5 Set Below 1 Ω


If the result is not as specified, replace the front door lock with motor assembly LH.



Hide 69030A 4.INSPECT FRONT DOOR LOCK WITH MOTOR ASSEMBLY RH (w/ Double Locking System)

a.
B228537C02
0.885,2.656 1.198,2.813 0.313,0.156 10 false *a 1.417,2.948 1.729,3.104 0.313,0.156 10 false *b 0.521,3.01 0.833,3.167 0.313,0.156 10 false *c
*a Unlock
*b Lock
*c Component without harness connected
(Front Door Lock with Motor Assembly RH)


Check the operation of the front door lock motor.

i.

Apply auxiliary battery voltage and check the operation of the front door lock motor and double lock motor.

OK:
Auxiliary Battery Connection Result
Auxiliary battery positive (+) → Terminal 2
Auxiliary battery negative (-) → Terminal 1
Locks
Auxiliary battery positive (+) → Terminal 1
Auxiliary battery negative (-) → Terminal 2
Unlocks
Auxiliary battery positive (+) → Terminal 4
Auxiliary battery negative (-) → Terminal 3
Sets
Auxiliary battery positive (+) → Terminal 3
Auxiliary battery negative (-) → Terminal 4
Unsets


HINT:
·

Move the door lock motor to the lock position and set the double locking system. Check that the doors cannot be unlocked by operating the control cable.

·

Move the door lock motor to the lock position and unset the double locking system. Check that the doors can be unlocked by operating the control cable.



If the result is not as specified, replace the front door lock with motor assembly RH.



b.

Check the operation of the door unlock detection switch and double lock position switch.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
7 - 8 Locked 10 kΩ or higher
7 - 8 Unlocked Below 1 Ω
9 - 10 Unset 10 kΩ or higher
9 - 10 Set Below 1 Ω


If the result is not as specified, replace the front door lock with motor assembly RH.



c.
B228539C02
0.094,0.969 0.406,1.125 0.313,0.156 10 false *a 1.208,0.792 1.521,0.948 0.313,0.156 10 false *b 0.531,0.615 0.844,0.771 0.313,0.156 10 false *c 0.604,2.99 0.917,3.146 0.313,0.156 10 false *d
*a Unlock
*b Lock
*c Neutral
*d Component without harness connected
(Front Door Lock with Motor Assembly RH)


Check the operation of the door key lock and unlock switch.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
6 - 8 Held to lock side Below 1 Ω
6 - 8 Neutral or held to unlock side 10 kΩ or higher
5 - 8 Held to unlock side Below 1 Ω
5 - 8 Neutral or held to lock side 10 kΩ or higher


If the result is not as specified, replace the front door lock with motor assembly RH.