Home › Engine / Hybrid System › CRUISE CONTROL › LANE DEPARTURE ALERT SYSTEM(w/ Steering Control)
RM3210E _51 Engine / Hybrid System _047527 CRUISE CONTROL _0239265 LANE DEPARTURE ALERT SYSTEM(w/ Steering Control) U

CRUISE CONTROL  LANE DEPARTURE ALERT SYSTEM(w/ Steering Control)  TERMINALS OF ECU  


CHECK FORWARD RECOGNITION CAMERA


NOTICE:
·

DTCs may be output when connectors are disconnected during inspection. Therefore, be sure to clear the DTCs using the GTS once the inspection has been completed.

·

Do not apply excessive force to the O7 forward recognition camera connector.



E256359E48
2.146,0.76 2.5,1 0.354,0.24 2.198,0.802 2.656,1 0.458,0.198 10 false O7

a.

Disconnect the O7 forward recognition camera connector.


b.

Measure the voltage and resistance according to the value(s) in the table below.

Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
O7-7 (IGB) - O7-10 (GND) LG - W-B Power source Power switch on (IG) 11 to 14 V
Power switch off Below 1 V
O7-10 (GND) - Body ground W-B - Body ground Ground Always Below 1 Ω


c.

Reconnect the O7 forward recognition camera connector.


d.

Check for pulses according to the value(s) in the table below.

HINT:

If the waveform is not similar to that shown in the illustration, a malfunction of a CAN bus line, terminating resistor, or the forward recognition camera is suspected.


Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
O7-5 (CA1P) - O7-10 (GND) GR - W-B CAN communication signal Power switch on (IG) Pulse generation
(See waveform 1)
O7-11 (CA1N) - O7-10 (GND) W - W-B CAN communication signal Power switch on (IG) Pulse generation
(See waveform 2)
O7-6 (CANH) - O7-10 (GND) G - W-B CAN communication signal Power switch on (IG) Pulse generation
(See waveform 1)
O7-12 (CANL) - O7-10 (GND) W - W-B CAN communication signal Power switch on (IG) Pulse generation
(See waveform 2)

i.
A086154E97
2.75,0.271 3.365,0.521 0.615,0.25 10 false 1 V/DIV. 1.365,1.906 2.313,2.094 0.948,0.188 10 false 10 μsec./DIV.

WAVEFORM 1

Item Content
Terminal Name Between O7-5 (CA1P) and O7-10 (GND)
Between O7-6 (CANH) and O7-10 (GND)
Tester Range 1 V/DIV., 10 μsec./DIV.
Condition Power switch on (IG)

HINT:

The waveform varies depending on the CAN communication signal.



ii.
A086155E89
2.76,0.281 3.396,0.51 0.635,0.229 10 false 1 V/DIV. 1.365,1.875 2.333,2.073 0.969,0.198 10 false 10 μsec./DIV.

WAVEFORM 2

Item Content
Terminal Name Between O7-11 (CA1N) and O7-10 (GND)
Between O7-12 (CANL) and O7-10 (GND)
Tester Range 1 V/DIV., 10 μsec./DIV.
Condition Power switch on (IG)

HINT:

The waveform varies depending on the CAN communication signal.





CHECK DRIVING SUPPORT ECU ASSEMBLY


E321781E26
3.396,0.115 3.833,0.354 0.438,0.24 3.5,0.156 4.115,0.354 0.615,0.198 10 false F40

a.

Measure the voltage and resistance according to the value(s) in the table below.

Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition

*1: for LHD

*2: for RHD

F40-7 (B) - F40-28 (GND) P - W-B *1
B - W-B *2
Power source Power switch on (IG) 11 to 14 V
Power switch off Below 1 V
F40-23 (SPSW) - F40-28 (GND) GR - W-B Steering pad switch signal
(Lane departure alert main switch signal)
Power switch off
Lane departure alert main switch off
1 MΩ or higher
Power switch off
Lane departure alert main switch on
228 to 252 Ω
F40-28 (GND) - Body ground W-B - Body ground Ground Always Below 1 Ω


b.

Check for pulses according to the value(s) in the table below.

HINT:

If the waveform is not similar to that shown in the illustration, a malfunction of a CAN bus line, terminating resistor, or the driving support ECU assembly is suspected.


Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
F40-8 (CA1P) - F40-28 (GND) LG - W-B CAN communication signal Power switch on (IG) Pulse generation
(See waveform 1)
F40-9 (CA1N) - F40-28 (GND) W - W-B CAN communication signal Power switch on (IG) Pulse generation
(See waveform 2)
F40-10 (CA2H) - F40-28 (GND) G - W-B CAN communication signal Power switch on (IG) Pulse generation
(See waveform 1)
F40-11 (CA2L) - F40-28 (GND) W - W-B CAN communication signal Power switch on (IG) Pulse generation
(See waveform 2)

i.
A086154E97
2.75,0.271 3.365,0.521 0.615,0.25 10 false 1 V/DIV. 1.365,1.906 2.313,2.094 0.948,0.188 10 false 10 μsec./DIV.

WAVEFORM 1

Item Content
Terminal Name Between F40-8 (CA1P) - F40-28 (GND)
Between F40-10 (CA2H) - F40-28 (GND)
Tester Range 1 V/DIV., 10 μsec./DIV.
Condition Power switch on (IG)

HINT:

The waveform varies depending on the CAN communication signal.



ii.
A086155E89
2.76,0.281 3.396,0.51 0.635,0.229 10 false 1 V/DIV. 1.365,1.875 2.333,2.073 0.969,0.198 10 false 10 μsec./DIV.

WAVEFORM 2

Item Content
Terminal Name Between F40-9 (CA1N) - F40-28 (GND)
Between F40-11 (CA2L) - F40-28 (GND)
Tester Range 1 V/DIV., 10 μsec./DIV.
Condition Power switch on (IG)

HINT: