88719A
1.INSPECT AIR CONDITIONER PRESSURE SENSOR
Check the wire harness.
Disconnect the A29 air conditioner pressure sensor connector.
Disconnect the F57 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A29-1 (-) - F57-2 (SG-2) | Always | Below 1 Ω |
| A29-2 (PR) - F57-24 (PRE) | Always | Below 1 Ω |
| A29-3 (+) - F57-6 (S5-3) | Always | Below 1 Ω |
| A29-1 (-) or F57-2 (SG-2) - Body ground | Always | 10 kΩ or higher |
| A29-2 (PR) or F57-24 (PRE) - Body ground | Always | 10 kΩ or higher |
| A29-3 (+) or F57-6 (S5-3) - Body ground | Always | 10 kΩ or higher |
If the resistance is not as specified, repair the wire harness.
Reconnect the F57 air conditioning amplifier assembly connector.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A29-3 (+) - Body ground | Power switch on (IG) | 4.75 to 5.25 V |
If the voltage is not as specified, repair the wire harness or replace air conditioning amplifier assembly.
Check the air conditioner pressure sensor.
Connect the connector to the air conditioner pressure sensor.
Install a manifold gauge set.
Turn the A/C switch on.
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
Measure the voltage according to the value(s) in the table below.
Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F57-24 (PRE) - F57-2 (SG-2) | Refrigerant pressure: Normal pressure (less than 3025 kPa (30.8 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 26 psi)) | 0.74 to 4.61 V |
If the voltage is not as specified, replace the air conditioner pressure sensor.