22204
1.INSPECT MASS AIR FLOW METER SUB-ASSEMBLY
Check the output voltage.
| *a | Component without harness connected
(Mass Air Flow Meter Sub-assembly) |
|
Air |
Connect a battery positive (+) lead to terminal 1 (+B) and negative (-) lead to terminal 2 (E2G).
While using the battery during inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
Connect the positive (+) tester probe to terminal 3 (VG) and negative (-) tester probe to terminal 2 (E2G).
Blow air into the mass air flow meter sub-assembly and check that the voltage fluctuates.
If the result is not as specified, replace the mass air flow meter sub-assembly.
| *a | Platinum Hot Wire (Heater) |
| *b | Temperature Sensor (Thermistor) |
Perform a visual check for any foreign matter on the platinum hot wire (heater) and temperature sensor (thermistor) of the mass air flow meter sub-assembly shown in the illustration.
There is no foreign matter.
If the result is not as specified, replace the mass air flow meter sub-assembly.
| *a | Component without harness connected
(Mass Air Flow Meter Sub-assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (THA) - 5 (E2) | -20°C (-4°F) | 12.5 to 16.9 kΩ |
| 20°C (68°F) | 2.19 to 2.67 kΩ | |
| 60°C (140°F) | 0.50 to 0.68 kΩ |
If the result is not as specified, replace the mass air flow meter sub-assembly.