Home › Drivetrain › P610 HYBRID TRANSMISSION / TRANSAXLE › ELECTRONIC SHIFT LEVER SYSTEM
RM3210E _52 Drivetrain _047503 P610 HYBRID TRANSMISSION / TRANSAXLE _0243554 ELECTRONIC SHIFT LEVER SYSTEM U

P610 HYBRID TRANSMISSION / TRANSAXLE  ELECTRONIC SHIFT LEVER SYSTEM  TERMINALS OF ECU  


CHECK HYBRID VEHICLE CONTROL ECU


C338835N06
1.25,0.323 1.667,0.583 0.417,0.26 3.271,0.292 3.688,0.552 0.417,0.26 5.313,0.302 5.729,0.563 0.417,0.26 1.323,0.365 1.781,0.563 0.458,0.198 10 false A50 3.385,0.344 3.844,0.542 0.458,0.198 10 false F2 5.417,0.344 5.875,0.542 0.458,0.198 10 false F3

HINT:

Measure the values on the wire harness side with the connector connected.


Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
A50-1 (MUA) - F2-12 (E01) B - W-B Parking lock motor Engine stopped (hybrid system stopped), power switch on (IG) 9 to 14 V
A50-2 (MVA) - F2-12 (E01) R - W-B Parking lock motor Engine stopped (hybrid system stopped), power switch on (IG) 9 to 14 V
A50-3 (MWA) - F2-12 (E01) W - W-B Parking lock motor Engine stopped (hybrid system stopped), power switch on (IG) 9 to 14 V
A50-5 (MREL) - F3-3 (E1) BE - W-B Main relay Power switch on (IG) 9 to 14 V
A50-11 (+B1) - F3-3 (E1) L - W-B Power source Engine stopped (hybrid system stopped), power switch on (IG) 9 to 14 V
A50-15 (BMA) - F3-3 (E1) R - W-B No. 1 integration relay (P-CON relay) Engine stopped (hybrid system stopped), power switch on (IG) 9 to 14 V
A50-16 (RA) - A50-44 (E2) LG - P Rotation angle sensor signal Power switch off → Power switch on (IG) 0 to 1.5 V ←→ 4 to 5.5 V
Power switch on (IG),
changing from park (P) to neutral (N), or neutral (N) to park (P)
Pulse generation (see waveform 1)
A50-41 (VC) - A50-44 (E2) G - P Power source (Rotation angle sensor) Engine stopped (hybrid system stopped), power switch on (IG) 4.5 to 5.5 V
A50-29 (RB) - A50-44 (E2) GR - P Rotation angle sensor signal Power switch off → Power switch on (IG) 0 to 1.5 V ←→ 4 to 5.5 V
Power switch on (IG),
changing from park (P) to neutral (N), or neutral (N) to park (P)
Pulse generation
(see waveform 1)
A50-44 (E2) - Body ground P - Body ground Rotation angle sensor ground Always Below 1 Ω
F2-7 (CA3P) - F3-3 (E1) G - W-B CAN communication signal Power switch on (IG) Pulse generation (see waveform 2)
F2-10 (E03) - Body ground W-B - Body ground Ground Always Below 1 Ω
F2-11 (E02) - Body ground W-B - Body ground Ground Always Below 1 Ω
F2-12 (E01) - Body ground W-B - Body ground Ground Always Below 1 Ω
F2-20 (CA3N) - F3-3 (E1) W - W-B CAN communication signal Power switch on (IG) Pulse generation (see waveform 2)
F2-34 (E12) - Body ground W-B - Body ground Ground Always Below 1 Ω
F3-1 (+B2) - F3-3 (E1) L - W-B Power source Power switch on (IG) 9 to 14 V
F3-3 (E1) - Body ground W-B - Body ground Ground Always Below 1 Ω
F3-6 (PPOS) - F3-3 (E1) V - W-B Transmission control communication signal Engine stopped (hybrid system stopped), power switch on (IG) Pulse generation (see waveform 3)
F3-13 (P1) - F3-3 (E1) LG - W-B P position switch signal Power switch on (IG), P position switch (transmission shift main switch) not pushed 7 to 12 V
Power switch on (IG), P position switch (transmission shift main switch) pushed 3 to 5 V
F3-27 (BATT) - F3-3 (E1) GR - W-B Power source (RAM) Always 9 to 14 V
F3-31 (LIN) L*1, BE*2 LIN communication - -
F3-39 (IND) - F3-3 (E1) P - W-B P position switch indicator light Park (P) not selected → Park (P) selected (P position switch (transmission shift main switch) pushed to select park (P)) 9 to 14 V → 0 to 1.5 V

*1: for LHD

*2: for RHD



OSCILLOSCOPE WAVEFORMS


HINT:

Oscilloscope waveform samples are provided here for reference only. Noise and flutuating waveforms have been omitted.


a.
A380050E02
0.146,1.406 0.604,1.604 0.458,0.198 10 false CH2 2.823,1.021 3.281,1.219 0.458,0.198 10 false GND 2.833,1.677 3.292,1.875 0.458,0.198 10 false GND 0.135,0.677 0.594,0.875 0.458,0.198 10 false CH1

Waveform 1 (Rotation angle sensor signal)

Item Contents
Terminal CH1: A50-16 (RA) - A50-44 (E2)
CH2: A50-29 (RB) - A50-44 (E2)
Equipment setting 2 V/DIV., 200 msec./DIV.
Condition Power switch on (IG),
changing from park (P) to neutral (N), or neutral (N) to park (P)

HINT:

When changing from park (P) to neutral (N), or neutral (N) to park (P) with the power switch on (IG), a waveform will be generated for up to 1.5 seconds.



b.
A294824E01
3.052,1.208 3.427,1.458 0.375,0.25 10 GND 3.063,1.573 3.427,1.823 0.365,0.25 10 GND 0.313,0.688 0.677,0.938 0.365,0.25 10 CH1 0.302,1.125 0.667,1.375 0.365,0.25 10 CH2

Waveform 2 (CAN communication signal)

Item Contents
Terminal CH1: F2-7 (CA3P) - F3-3 (E1)
CH2: F2-20 (CA3N) - F3-3 (E1)
Equipment setting 1 V/DIV., 50 μs/DIV.
Condition Power switch on (IG)


c.
C338836E01
2.885,1.01 3.344,1.208 0.458,0.198 10 false GND

Waveform 3 (Transmission control communication signal)

Item Contents
Terminal F3-6 (PPOS) - F3-3 (E1)
Equipment setting 10 V/DIV., 10 ms/DIV.
Condition Engine stopped (hybrid system stopped), power switch on (IG)