DATA LIST
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Room Temperature Sensor | Cooler (room temp. sensor) thermistor | Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F) |
Actual cabin temperature displayed | - |
| Ambient Temp Sensor | Thermistor assembly | Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed | - |
| Adjusted Ambient Temp | Adjusted ambient temperature | Min.: -30.80°C (-23.44°F)
Max.: 50.80°C (123.44°F) |
- | - |
| Evaporator Fin Thermistor | No. 1 cooler thermistor | Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | - |
| Evaporator Target Temp | Evaporator target temperature | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Evaporator target temperature displayed | - |
| Solar Sensor (D Side) | Driver side solar sensor*2 or solar sensor*3 | Min.: 0
Max.: 255 |
Driver side solar sensor*2 or solar sensor*3 value increases as brightness increases | - |
| Solar Sensor (P Side) | Front passenger side solar sensor | Min.: 0
Max.: 255 |
Front passenger side solar sensor value increases as brightness increases | *2 |
| Engine Coolant Temp | Engine coolant temperature sensor | Min.: 1.30°C (34.34°F)
Max.: 90.55°C (194.99°F) |
Actual engine coolant temperature displayed | - |
| Blower Motor Speed Level | Blower motor speed level | Min.: 0
Max.: 31 |
Displayed speed level increases in range between 0 and 31 as blower motor speed increases | - |
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -456.6 kPaG
Max.: 3294.3 kPaG |
Actual refrigerant pressure displayed | - |
| Air Outlet Servo Pulse (R) | No. 3 air conditioning radiator damper servo sub-assembly target pulse | Min.: 128
Max.: 383 |
·
FACE: 250 (pulse) ·
B/L: 281 (pulse) ·
FOOT-F: 287 (pulse) ·
FOOT: 297 (pulse) ·
S-FLOW (Front Seat Control Modes): 250 (pulse) |
- |
| Air Outlet Servo Actual Pls(R) | No. 3 air conditioning radiator damper servo sub-assembly actual pulse | Min.: 128
Max.: 383 |
·
FACE: 250 (pulse) ·
B/L: 281 (pulse) ·
FOOT-F: 287 (pulse) ·
FOOT: 297 (pulse) ·
S-FLOW (Front Seat Control Modes): 250 (pulse) |
- |
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix*2 or air mix*3) target pulse | Min.: 128
Max.: 383 |
for LHD:
·
MAX COLD: 257 (pulse) ·
MAX HOT: 165 (pulse) for RHD:
·
MAX COLD: 255 (pulse) ·
MAX HOT: 347 (pulse) |
- |
| Air Mix Servo Actual Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix*2 or air mix*3) actual pulse | Min.: 128
Max.: 383 |
for LHD:
·
MAX COLD: 257 (pulse) ·
MAX HOT: 165 (pulse) for RHD:
·
MAX COLD: 255 (pulse) ·
MAX HOT: 347 (pulse) |
- |
| Air Mix Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) target pulse | Min.: 128
Max.: 383 |
for LHD:
·
MAX COLD: 255 (pulse) ·
MAX HOT: 347 (pulse) for RHD:
·
MAX COLD: 257 (pulse) ·
MAX HOT: 165 (pulse) |
*2 |
| Air Mix Servo Actual Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) actual pulse | Min.: 128
Max.: 383 |
for LHD:
·
MAX COLD: 255 (pulse) ·
MAX HOT: 347 (pulse) for RHD:
·
MAX COLD: 257 (pulse) ·
MAX HOT: 165 (pulse) |
*2 |
| Air Outlet Servo Pulse (D) | for LHD:
No. 2 air conditioning radiator damper servo sub-assembly target pulse for RHD:
No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) target pulse |
Min.: 128
Max.: 383 |
for LHD:
·
FACE: 256 (pulse) ·
FACE1: 256 (pulse) ·
FACE2: 256 (pulse) ·
B/L: 245 (pulse) ·
B/L2: 245 (pulse) ·
FOOT-R: 215 (pulse) ·
FOOT-M: 215 (pulse) ·
FOOT: 215 (pulse) ·
FOOT-D: 207 (pulse) ·
FOOT-0: 224 (pulse) ·
FOOT-F: 215 (pulse) ·
FOOT/DEF: 192 (pulse) ·
DEF: 164 (pulse) ·
S-FLOW (Single Seat Control Modes): 164 (pulse) for RHD:
·
FACE: 256 (pulse) ·
FACE1: 256 (pulse) ·
FACE2: 256 (pulse) ·
B/L: 267 (pulse) ·
B/L2: 267 (pulse) ·
FOOT-R: 297 (pulse) ·
FOOT-M: 297 (pulse) ·
FOOT: 297 (pulse) ·
FOOT-D: 305 (pulse) ·
FOOT-0: 288 (pulse) ·
FOOT-F: 297 (pulse) ·
FOOT/DEF: 320 (pulse) ·
DEF: 348 (pulse) ·
S-FLOW (Single Seat Control Modes): 348 (pulse) |
- |
| Air Outlet Servo Actu Pulse(D) | for LHD:
No. 2 air conditioning radiator damper servo sub-assembly actual pulse for RHD:
No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) actual pulse |
Min.: 128
Max.: 383 |
for LHD:
·
FACE: 256 (pulse) ·
FACE1: 256 (pulse) ·
FACE2: 256 (pulse) ·
B/L: 245 (pulse) ·
B/L2: 245 (pulse) ·
FOOT-R: 215 (pulse) ·
FOOT-M: 215 (pulse) ·
FOOT: 215 (pulse) ·
FOOT-D: 207 (pulse) ·
FOOT-0: 224 (pulse) ·
FOOT-F: 215 (pulse) ·
FOOT/DEF: 192 (pulse) ·
DEF: 164 (pulse) ·
S-FLOW (Single Seat Control Modes): 164 (pulse) for RHD:
·
FACE: 256 (pulse) ·
FACE1: 256 (pulse) ·
FACE2: 256 (pulse) ·
B/L: 267 (pulse) ·
B/L2: 267 (pulse) ·
FOOT-R: 297 (pulse) ·
FOOT-M: 297 (pulse) ·
FOOT: 297 (pulse) ·
FOOT-D: 305 (pulse) ·
FOOT-0: 288 (pulse) ·
FOOT-F: 297 (pulse) ·
FOOT/DEF: 320 (pulse) ·
DEF: 348 (pulse) ·
S-FLOW (Single Seat Control Modes): 348 (pulse) |
- |
| Air Outlet Servo Targ Pulse(P) | for LHD:
No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) target pulse for RHD:
No. 2 air conditioning radiator damper servo sub-assembly target pulse |
Min.: 128
Max.: 383 |
for LHD:
·
FACE: 256 (pulse) ·
FACE1: 256 (pulse) ·
FACE2: 256 (pulse) ·
B/L: 267 (pulse) ·
B/L2: 267 (pulse) ·
FOOT-R: 297 (pulse) ·
FOOT-M: 297 (pulse) ·
FOOT: 297 (pulse) ·
FOOT-D: 305 (pulse) ·
FOOT-0: 288 (pulse) ·
FOOT-F: 297 (pulse) ·
FOOT/DEF: 320 (pulse) ·
DEF: 348 (pulse) ·
S-FLOW (Single Seat Control Modes): 348 (pulse) for RHD:
·
FACE: 256 (pulse) ·
FACE1: 256 (pulse) ·
FACE2: 256 (pulse) ·
B/L: 245 (pulse) ·
B/L2: 245 (pulse) ·
FOOT-R: 215 (pulse) ·
FOOT-M: 215 (pulse) ·
FOOT: 215 (pulse) ·
FOOT-D: 207 (pulse) ·
FOOT-0: 224 (pulse) ·
FOOT-F: 215 (pulse) ·
FOOT/DEF: 192 (pulse) ·
DEF: 164 (pulse) ·
S-FLOW (Single Seat Control Modes): 164 (pulse) |
- |
| Air Outlet Servo Actu Pulse(P) | for LHD:
No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) actual pulse for RHD:
No. 2 air conditioning radiator damper servo sub-assembly actual pulse |
Min.: 128
Max.: 383 |
for LHD:
·
FACE: 256 (pulse) ·
FACE1: 256 (pulse) ·
FACE2: 256 (pulse) ·
B/L: 267 (pulse) ·
B/L2: 267 (pulse) ·
FOOT-R: 297 (pulse) ·
FOOT-M: 297 (pulse) ·
FOOT: 297 (pulse) ·
FOOT-D: 305 (pulse) ·
FOOT-0: 288 (pulse) ·
FOOT-F: 297 (pulse) ·
FOOT/DEF: 320 (pulse) ·
DEF: 348 (pulse) ·
S-FLOW (Single Seat Control Modes): 348 (pulse) for RHD:
·
FACE: 256 (pulse) ·
FACE1: 256 (pulse) ·
FACE2: 256 (pulse) ·
B/L: 245 (pulse) ·
B/L2: 245 (pulse) ·
FOOT-R: 215 (pulse) ·
FOOT-M: 215 (pulse) ·
FOOT: 215 (pulse) ·
FOOT-D: 207 (pulse) ·
FOOT-0: 224 (pulse) ·
FOOT-F: 215 (pulse) ·
FOOT/DEF: 192 (pulse) ·
DEF: 164 (pulse) ·
S-FLOW (Single Seat Control Modes): 164 (pulse) |
- |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly target pulse | Min.: 128
Max.: 383 |
·
Recirculation: 256 (pulse) ·
Fresh: 220 (pulse) |
- |
| Air Inlet Damper Actual Pulse | No. 1 blower damper servo sub-assembly actual pulse | Min.: 128
Max.: 383 |
·
Recirculation: 256 (pulse) ·
Fresh: 220 (pulse) |
- |
| Electric Heater Count | Maximum electric heater operation level | Min.: 0
Max.: 3 |
Maximum possible operation level of electric heater displayed | *1 |
| Electric Heater Active Level | Actual electric heater operation level | Min.: 0
Max.: 3 |
Actual operation level of electric heater displayed | *1 |
| Compressor Speed | Compressor speed | Min.: 0 rpm
Max.: 65535 rpm |
Actual compressor speed displayed | - |
| Compressor Target Speed | Compressor target speed | Min.: 0 rpm
Max.: 65535 rpm |
Compressor target speed displayed | - |
| Shift Set Temperature | Shift set temperature | 2C decr, 1C decr, Normal, 1C incr, 2C incr | Customized value displayed | - |
| Air Inlet Mode | Air inlet mode | Auto or Manual | Customized value displayed | *4 |
| Noise and Vibration Reduction | Noise and vibration reduction | OFF or ON | Customized value displayed | - |
| ECO MODE Cancel | ECO drive mode cancel | OFF or ON | Customized value displayed | - |
| ECO Switch | - | - | - | Not applicable to the vehicle |
| Refrigerant Shortage Check | Refrigerant shortage check | ON or OFF | Customized value displayed | - |
| Fan speed increment control | Fan speed increment control | Slow, Normal, Fast | Customized value displayed | - |
| Foot/DEF Auto Mode | Foot/defroster auto mode | ON or OFF | Customized value displayed | - |
| Foot/DEF Auto Blow Up | Foot/defroster auto blower speed increase | ON or OFF | Customized value displayed | - |
| Ambient Temperature Shift | Ambient temperature shift | 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr, 3C incr | Customized value displayed | - |
| Compressor Drive Check | Compressor drive check | OK or NG | NG: Compressor does not operate
OK: Compressor operates |
- |
| Glass Temperature | Windshield glass temperature | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Actual windshield glass temperature is displayed | - |
| Glass Surroundings Temperature | Temperature around windshield glass | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Actual temperature around windshield glass is displayed | - |
| Glass Humidity | Windshield glass humidity | Min.: 0.00%
Max.: 100.00% |
Actual windshield glass humidity is displayed | - |
| Refrigerant Gas Type | Refrigerant gas type | R134a or 1234yf | Refrigerant gas type displayed | - |
| Set Temperature (D Side) | Driver side set temperature | Min.: MAX COLD
Max.: MAX HOT |
Driver side set temperature displayed | - |
| Set Temperature (P Side) | Front passenger side set temperature | Min.: MAX COLD
Max.: MAX HOT |
Front passenger side set temperature displayed | *2 |
| Outside Air Mode Auto Switch Function | Outside air mode auto switch function | ON or OFF | Customized value displayed | *4 |
| S-FLOW Control Auto Function | S-FLOW control auto function | ON or OFF | Customized value displayed | - |
| Communication Wiper ECU | Existence of function | With or Without | With: w/ Wiper ECU
Without: w/o Wiper ECU |
- |
| Communication Wiper Switch | Existence of function | With or Without | With: w/ Wiper switch
Without: w/o Wiper switch |
- |
| Communication Humidity/Rain Sensor | Existence of function | With or Without | With: w/ Humidity sensor
Without: w/o Humidity sensor |
- |
| Number of Trouble Codes | Number of trouble codes | Min.: 0
Max.: 255 |
Number of DTCs displayed | - |
*1: w/ PTC Heater
*2: for Dual Type
*3: for Single Type
*4: w/ Rear Seat Belt Warning
ACTIVE TEST
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower motor with fan sub-assembly | Min.: 0, Max.: 31 | - |
| Compressor Target Speed | Compressor with motor assembly | Min.: 0, Max.: 7500 | - |
| Defogger Relay (Rear) | Rear window defogger | OFF, ON | - |
| Heater Active Level | Quick heater assembly | Min.: 0, Max.: 3 | *1 |
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix*2 or air mix*3) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 165 to 257 pulses for RHD:
Operates between 255 to 347 pulses |
| Air Mix Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse*2 | Min.: 128
Max.: 383 |
for LHD:
Operates between 255 to 347 pulses for RHD:
Operates between 165 to 257 pulses |
| Air Outlet Servo Pulse (D) | for LHD:
No. 2 air conditioning radiator damper servo sub-assembly pulse for RHD:
No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) pulse |
Min.: 128
Max.: 383 |
for LHD:
Operates between 164 to 256 pulses for RHD:
Operates between 256 to 348 pulses |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 220 to 256 pulses |
| Air Outlet Servo Pulse (P) | for LHD:
No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) pulse for RHD:
No. 2 air conditioning radiator damper servo sub-assembly pulse |
Min.: 128
Max.: 383 |
for LHD:
Operates between 256 to 348 pulses for RHD:
Operates between 164 to 256 pulses |
| A/O Servo Pulse(Rr D) | No. 3 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 250 to 297 pulses |
*1: w/ PTC Heater
*2: for Dual Type
*3: for Single Type
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Control the Electric Cooling Fan | Control electric cooling fan motor | ON/OFF | Perform this test when the following conditions are met:
·
Power switch is on (IG) ·
Engine is stopped ·
Shift lever in P |