HYBRID / BATTERY CONTROL  HV RELAY ASSEMBLY  INSPECTION  


PROCEDURE

Hide G92Z0 1.INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY

a.

Inspect SMRB:

i.

Measure the resistance according to the value(s) in the table below.

A378136C24
3.844,1.073 4.208,1.281 0.365,0.208 3.167,0.208 3.552,0.427 0.385,0.219 5.625,0.177 6.042,0.385 0.417,0.208 3.385,1.188 3.094,1.354 true 3.604,1.188 3.844,1.375 true 3.021,0.406 3.354,0.667 true 5.813,0.708 6.313,1.125 true 0.104,0.094 0.417,0.25 0.313,0.156 10 false *a 3.708,1.385 4.177,1.552 0.469,0.167 10 true SMRB 2.927,1.385 3.271,1.604 0.344,0.219 10 true GND 2.677,0.313 2.979,0.479 0.302,0.167 10 true CBI 3.896,1.104 4.208,1.26 0.313,0.156 10 false M37 3.229,0.24 3.479,0.406 0.25,0.167 10 true S4 6.396,1.115 6.573,1.313 0.177,0.198 10 true + 5.688,0.198 5.979,0.354 0.292,0.156 10 true A
*a Component without harness connected
(HV Battery Junction Block Assembly)
- -


Standard Resistance:
Tester Connection Condition Specified Condition
S4-1 (CBI) - A-1 (+) Auxiliary battery voltage not applied between terminals M37-1 (SMRB) and M37-3 (GND) 10 kΩ or higher
Auxiliary battery voltage applied between terminals M37-1 (SMRB) and M37-3 (GND) Below 1 Ω



ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
M37-1 (SMRB) - M37-3 (GND) -40 to 80°C (-40 to 176°F) 20.6 to 40.8 Ω


If the result is not as specified, replace the HV battery junction block assembly.



b.

Inspect SMRG:

i.

Measure the resistance according to the value(s) in the table below.

A378136C41
3.844,1 4.208,1.208 0.365,0.208 1.156,0.167 1.521,0.375 0.365,0.208 2.24,0.177 2.604,0.385 0.365,0.208 3.385,1.188 3.573,1.375 true 3.271,1.177 3.063,1.365 true 1.323,0.656 0.74,0.958 true 2.063,0.542 2.385,0.656 true 0.104,0.094 0.417,0.25 0.313,0.156 10 false *a 3.896,1.042 4.208,1.198 0.313,0.156 10 false M37 3.469,1.396 3.833,1.583 0.365,0.188 10 true GND 2.865,1.396 3.354,1.583 0.49,0.188 10 true SMRG 0.604,0.99 0.823,1.135 0.219,0.146 10 true - 1.198,0.198 1.49,0.344 0.292,0.146 10 true z12 2.292,0.208 2.531,0.354 0.24,0.146 10 true S3 1.74,0.458 2.031,0.635 0.292,0.177 10 true CEI
*a Component without harness connected
(HV Battery Junction Block Assembly)
- -


Standard Resistance:
Tester Connection Condition Specified Condition
S3-1 (CEI) - z12-1 (-) Auxiliary battery voltage not applied between terminals M37-4 (SMRG) and M37-3 (GND) 10 kΩ or higher
Auxiliary battery voltage applied between terminals M37-4 (SMRG) and M37-3 (GND) Below 1 Ω



ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
M37-4 (SMRG) - M37-3 (GND) -40 to 80°C (-40 to 176°F) 20.6 to 40.8 Ω


If the result is not as specified, replace the HV battery junction block assembly.



c.

Inspect SMRP:

i.

Measure the resistance according to the value(s) in the table below.

A378136C42
3.844,1 4.208,1.208 0.365,0.208 1.156,0.167 1.521,0.375 0.365,0.208 2.24,0.177 2.604,0.385 0.365,0.208 3.51,1.188 3.698,1.375 true 3.396,1.177 3.188,1.365 true 1.323,0.656 0.74,0.958 true 2.063,0.542 2.385,0.656 true 0.104,0.094 0.417,0.25 0.313,0.156 10 false *a 3.896,1.042 4.208,1.198 0.313,0.156 10 false M37 3.021,1.396 3.375,1.563 0.354,0.167 10 true GND 3.552,1.396 4.042,1.573 0.49,0.177 10 true SMRP 0.594,0.99 0.813,1.135 0.219,0.146 10 true - 1.198,0.198 1.49,0.344 0.292,0.146 10 true z12 2.292,0.208 2.552,0.365 0.26,0.156 10 true S3 1.75,0.458 2.031,0.646 0.281,0.188 10 true CEI
*a Component without harness connected
(HV Battery Junction Block Assembly)
- -


Standard Resistance:
Tester Connection Condition Specified Condition
S3-1 (CEI) - z12-1 (-) Auxiliary battery voltage applied between terminals M37-2 (SMRP) and M37-3 (GND) 10 kΩ or higher
Auxiliary battery voltage applied between terminals M37-2 (SMRP) and M37-3 (GND) 24.3 and 29.7 Ω



ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
M37-2 (SMRP) - M37-3 (GND) -40 to 80°C (-40 to 176°F) 140 to 290 Ω


If the result is not as specified, replace the HV battery junction block assembly.