Home › Audio / Visual / Telematics › PARK ASSIST / MONITORING › INTELLIGENT CLEARANCE SONAR SYSTEM
RM3210E _56 Audio / Visual / Telematics _047512 PARK ASSIST / MONITORING _0244854 INTELLIGENT CLEARANCE SONAR SYSTEM U

PARK ASSIST / MONITORING  INTELLIGENT CLEARANCE SONAR SYSTEM  DATA LIST / ACTIVE TEST  


DATA LIST


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / IPA/ICS/Clearance Sonar / Data List.


e.

Read the Data List according to the display on the GTS.

Body Electrical > IPA/ICS/Clearance Sonar > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Initial Steering Angle Set Status of initial steering angle setting Not Yet or Done Not Yet: Not completed
Done: Completed
-
Current Steering Angle Set Status of current steering angle setting Unset or Set Unset: Not completed
Set: Completed
-
ICS SW Status Intelligent clearance sonar system switch assembly (Multi-information switch) OFF or ON OFF: Intelligent clearance sonar system off
ON: Intelligent clearance sonar system on
-
Fr Sensor Onset Range Detection operation range (for front center sensors) Narrow or Wide Narrow: 600 mm (23.6 in.)
Wide: 1000 mm (39.4 in.)
Customized value displayed
Rr Sensor Onset Range Detection operation range (for rear center sensors) Narrow or Wide Narrow: 600 mm (23.6 in.)
Wide: 1500 mm (59.1 in.)
Customized value displayed
Keep Sense Buzzer Keep sense buzzer operation Not Avail or Avail Not Avail: Buzzer stops
Avail: Buzzer sounds continuously
Customized value displayed
Fr & Rr Buzzer Volume Buzzer volume setting L, M1, M2, M3 or H L: Low volume
M1: Medium low volume
M2: Medium volume
M3: Medium high volume
H: High volume
Customized value displayed
Sensor Condition N Front sensor operation Not Avail or Avail Not Avail: Front sensors not available
Avail: Front sensors available
Customized value displayed
Approach Display OFF Whether the display turns off after an obstacle is no longer detected. Not Avail or Avail Not Avail: Not displayed
Avail: Displayed
Customized value displayed
Target 1 Distance (FLC Sensor) Distance between ultrasonic sensor and target object Unknown, Not Detected or 0.00 to 7.65 m (0.00 to 25.09 ft.) Unknown: Detection conditions not met
Not Detected: No objects detected
0.00 to 7.65 m (0.00 to 25.09 ft.): Detected distance
-
Target 1 Distance (FRC Sensor) Distance between ultrasonic sensor and target object Unknown, Not Detected or 0.00 to 7.65 m (0.00 to 25.09 ft.) Unknown: Detection conditions not met
Not Detected: No objects detected
0.00 to 7.65 m (0.00 to 25.09 ft.): Detected distance
-
Target 1 Distance (RLC Sensor) Distance between ultrasonic sensor and target object Unknown, Not Detected or 0.00 to 7.65 m (0.00 to 25.09 ft.) Unknown: Detection conditions not met
Not Detected: No objects detected
0.00 to 7.65 m (0.00 to 25.09 ft.): Detected distance
-
Target 1 Distance (RRC Sensor) Distance between ultrasonic sensor and target object Unknown, Not Detected or 0.00 to 7.65 m (0.00 to 25.09 ft.) Unknown: Detection conditions not met
Not Detected: No objects detected
0.00 to 7.65 m (0.00 to 25.09 ft.): Detected distance
-
Target 1 Distance (FL Sensor) Distance between ultrasonic sensor and target object Unknown, Not Detected or 0.00 to 5.10 m Unknown: Detection conditions not met
Not Detected: No objects detected
0.00 to 5.10 m (0.00 to 16.73 ft.): Detected distance
-
Target 1 Distance (FR Sensor) Distance between ultrasonic sensor and target object Unknown, Not Detected or 0.00 to 5.10 m (0.00 to 16.73 ft.) Unknown: Detection conditions not met
Not Detected: No objects detected
0.00 to 5.10 m (0.00 to 16.73 ft.): Detected distance
-
Target 1 Distance (RL Sensor) Distance between ultrasonic sensor and target object Unknown, Not Detected or 0.00 to 5.10 m (0.00 to 16.73 ft.) Unknown: Detection conditions not met
Not Detected: No objects detected
0.00 to 5.10 m (0.00 to 16.73 ft.): Detected distance
-
Target 1 Distance (RR Sensor) Distance between ultrasonic sensor and target object Unknown, Not Detected or 0.00 to 5.10 m (0.00 to 16.73 ft.) Unknown: Detection conditions not met
Not Detected: No objects detected
0.00 to 5.10 m (0.00 to 16.73 ft.): Detected distance
-
Target 2 Distance (FLC Sensor) Distance between ultrasonic sensor and target object Unknown, Not Detected or 0.00 to 7.65 m Unknown: Detection conditions not met
Not Detected: No objects detected
0.00 to 7.65 m (0.00 to 25.09 ft.): Detected distance
-
Target 2 Distance (FRC Sensor) Distance between ultrasonic sensor and target object Unknown, Not Detected or 0.00 to 7.65 m (0.00 to 25.09 ft.) Unknown: Detection conditions not met
Not Detected: No objects detected
0.00 to 7.65 m (0.00 to 25.09 ft.): Detected distance
-
Target 2 Distance (RLC Sensor) Distance between ultrasonic sensor and target object Unknown, Not Detected or 0.00 to 7.65 m (0.00 to 25.09 ft.) Unknown: Detection conditions not met
Not Detected: No objects detected
0.00 to 7.65 m (0.00 to 25.09 ft.): Detected distance
-
Target 2 Distance (RRC Sensor) Distance between ultrasonic sensor and target object Unknown, Not Detected or 0.00 to 7.65 m (0.00 to 25.09 ft.) Unknown: Detection conditions not met
Not Detected: No objects detected
0.00 to 7.65 m (0.00 to 25.09 ft.): Detected distance
-
Target 2 Distance (FL Sensor) Distance between ultrasonic sensor and target object Unknown, Not Detected or 0.00 to 5.10 m (0.00 to 16.73 ft.) Unknown: Detection conditions not met
Not Detected: No objects detected
0.00 to 5.10 m (0.00 to 16.73 ft.): Detected distance
-
Target 2 Distance (FR Sensor) Distance between ultrasonic sensor and target object Unknown, Not Detected or 0.00 to 5.10 m (0.00 to 16.73 ft.) Unknown: Detection conditions not met
Not Detected: No objects detected
0.00 to 5.10 m (0.00 to 16.73 ft.): Detected distance
-
Target 2 Distance (RL Sensor) Distance between ultrasonic sensor and target object Unknown, Not Detected or 0.00 to 5.10 m (0.00 to 16.73 ft.) Unknown: Detection conditions not met
Not Detected: No objects detected
0.00 to 5.10 m (0.00 to 16.73 ft.): Detected distance
-
Target 2 Distance (RR Sensor) Distance between ultrasonic sensor and target object Unknown, Not Detected or 0.00 to 5.10 m (0.00 to 16.73 ft.) Unknown: Detection conditions not met
Not Detected: No objects detected
0.00 to 5.10 m (0.00 to 16.73 ft.): Detected distance
-
ICS Function Current setting of intelligent clearance sonar system ON or OFF ON: Intelligent clearance sonar system enabled
OFF: Intelligent clearance sonar system disabled
Customized value displayed
ICS System Existence of intelligent clearance sonar system Without or With Without: w/o Intelligent clearance sonar system
With: w/ Intelligent clearance sonar system
-
ICS Stop Distance Target stop distance Short or Long Short: Near
Long: Far
Customized value displayed
ICS SW Status Memory Setting that determines if the on/off operation state when the power switch is turned off is resumed when the power switch is turned on Yes or No Yes: Previous on/off operation state is resumed
No: System operates when the power switch is turned on
Customized value displayed
Bumper Type Registered bumper type Unfixed or 1 to 127 1: Standard
2 to 127: Unknown
Unfixed: Unknown
-
# Codes Number of stored DTCs min.: 0, max.: 255 Number of DTCs will be displayed -


ACTIVE TEST


HINT:

Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Chassis / ABS/VSC/TRAC / Active Test.


e.

According to the display on the GTS, perform the Active Test.

Chassis > ABS/VSC/TRAC > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Stop Light Relay Stop lights ON / OFF Test possible at vehicle speed of 0 km/h (0 mph)

f.

Enter the following menus: Body Electrical / Combination Meter / Active Test.


g.

According to the display on the GTS, perform the Active Test.

Body Electrical > Combination Meter > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
ICS OFF Indicator ICS OFF indicator light ON / OFF -

h.

Enter the following menus: Body Electrical / IPA/ICS/Clearance Sonar / Active Test.


i.

According to the display on the GTS, perform the Active Test.

Body Electrical > IPA/ICS/Clearance Sonar > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Front Buzzer No. 1 clearance warning buzzer Stop or Operate Confirm that the vehicle is stopped and the power switch is on (IG)
Rear Buzzer No. 2 clearance warning buzzer Stop or Operate Confirm that the vehicle is stopped and the power switch is on (IG)