Home › General › SPECIFICATIONS › 2ZR-FXE BATTERY / CHARGING
RM3210E _V1 General _047544 SPECIFICATIONS _0224727 2ZR-FXE BATTERY / CHARGING F

SPECIFICATIONS  2ZR-FXE BATTERY / CHARGING  SERVICE DATA  


Auxiliary battery voltage Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal 20°C (68°F), Power switch off 12.0 V or higher
Auxiliary battery is OK
12.0 V or less
Recharge auxiliary battery
Fuse Standard resistance Below 1 Ω

Recharge auxiliary battery
Charge Method Charging Current
Normal Below 5 A
Quick Below 15 A

DC/DC CONVERTER
Item Tester Connection Condition Specified Condition
Current flowing from auxiliary battery Positive (+) auxiliary battery cable Power switch on (READY)
(The high beam headlights are on, the blower motor switch is in the HI position, and the rear window defogger is turned on.)
Below 0 A
(no current from auxiliary battery)
Auxiliary battery voltage Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal 13 to 15 V