Home › Power Source / Network › 2ZR-FXE BATTERY / CHARGING › CHARGING SYSTEM
RM3210E _57 Power Source / Network _047502 2ZR-FXE BATTERY / CHARGING _0244883 CHARGING SYSTEM L

2ZR-FXE BATTERY / CHARGING  CHARGING SYSTEM  PRECAUTION  


INITIALIZATION


NOTICE:

When disconnecting the cable from the negative (-) auxiliary battery terminal, initialize the following system(s) after the cable is reconnected.

System Name See Procedure
Lane Departure Alert System (w/ Steering Control) (Click here)
Intelligent Clearance Sonar System
Parking Assist Monitor System
Simple Intelligent Parking Assist System
Power Door Lock Control System
Pre-crash Safety System



CHARGING SYSTEM PRECAUTION


CAUTION:
·
A340386

Orange wire harnesses and connectors indicate high-voltage circuits. To prevent electric shock, always follow the procedure described in the repair manual.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION

·
A340358

To prevent electric shock, wear insulated gloves when working on wire harnesses and components of the high voltage system.



NOTICE:
·

If the auxiliary battery is fully depleted or the READY indicator does not illuminate, recharge the auxiliary battery.

·

Never disconnect the auxiliary battery while the power switch is on (READY).

·

Before giving the auxiliary battery a quick charge, disconnect the auxiliary battery cables.

·

Check the auxiliary battery again before the vehicle is returned to the customer.

·

When replacing the auxiliary battery, use a new auxiliary battery of the same dimensions with a capacity of 51 Ah or more at a 20-hour rate.