1.INSPECT R/MIR (+) RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 4 | Auxiliary battery voltage applied to terminals 1 and 2 | 10 kΩ or higher |
| 3 - 4 | Auxiliary battery voltage not applied between terminals | Below 1 Ω |
| 3 - 5 | Auxiliary battery voltage applied to terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | Auxiliary battery voltage not applied between terminals | 10 kΩ or higher |
| 4 - 5 | Always | 10 kΩ or higher |
If the result is not as specified, replace the R/MIR (+) relay.
2.INSPECT R/MIR (-) RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 4 | Auxiliary battery voltage applied to terminals 1 and 2 | 10 kΩ or higher |
| 3 - 4 | Auxiliary battery voltage not applied between terminals | Below 1 Ω |
| 3 - 5 | Auxiliary battery voltage applied to terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | Auxiliary battery voltage not applied between terminals | 10 kΩ or higher |
| 4 - 5 | Always | 10 kΩ or higher |
If the result is not as specified, replace the R/MIR (-) relay.