ON-VEHICLE INSPECTION
Inspection · Vehicles built from Nov 2005
| CHECK PRESSURE SENSOR |
Check the wire harness.

Disconnect the connector of the pressure sensor.
Measure the resistance of the wire harness side connector.
- Standard resistance:
Tester Connection
Specified Condition
1 - Body ground
Below 1 Ω
Turn the ignition switch on (IG).
Measure the voltage of the wire harness side connector.
- Standard voltage:
Tester Connection
Specified Condition
1 - 3
4.7 to 5.3 V
- If the result is not as specified, replace the pressure sensor.
Check the pressure sensor.

Set the manifold gauge.
Connect the connector to the pressure sensor.
Warm up the engine.
Switch the A/C ON.
Measure the voltage.
- Standard voltage:
Tester Connection
Refrigerant Pressure
Specified Condition
for Automatic Air Conditioner:
E41-9 (PRE) - E41-13 (SG-2)
0.176 to 3.025 MPa (1.8 to 30.9 kgf/cm2)
0.76 to 4.74 V
for Manual Air Conditioner:
E42-12 (PRE) - E42-10 (SG-2)
0.176 to 3.025 MPa (1.8 to 30.9 kgf/cm2)
0.76 to 4.74 V
- If the result is not as specified, replace the pressure sensor.