P0748 Pressure Control Solenoid "A" Electrical (Shift Solenoid Valve SL1)
Diagnostic trouble codes · Vehicles built from Nov 2005
DESCRIPTION
Shifting from 1st to O/D is performed in combination with the ON and OFF operation of the shift solenoid valves SL1 and SL2, which are controlled by the ECM. If an open or short circuit occurs in any of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated safely (Click here).| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0748 |
Duty cycle to shift solenoid valve SL1 is 100% (1 trip detection logic) |
|
MONITOR DESCRIPTION
This DTC indicates an open or short in the shift solenoid valve SL1 circuit. The ECM commands gear shifts by turning the shift solenoid valves ON/OFF. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. Also, the ECM performs the fail-safe function and turns the other normal shift solenoid valves ON/OFF. In case of an open or short circuit, the ECM stops sending current to the circuit (Click here).WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL1) |
Disconnect the B29 wire connector.

Measure the resistance of the transmission wire.
- Standard resistance:
Tester Connection
Condition
Specified Condition
5 (SL1+) - 10 (SL1-)
20°C (68°F)
5.0 to 5.6 Ω
5 (SL1+) - Body ground
20°C (68°F)
10 kΩ or higher
10 (SL1-) - Body ground
20°C (68°F)
10 kΩ or higher
|
|
||||
| OK | |
| 2. CHECK WIRE HARNESS (TRANSMISSION WIRE - ECM) |
Connect the B29 wire connector.
Disconnect the B32 ECM connector.

Measure the resistance of the wire harness side connector.
- Standard resistance:
Tester Connection
Condition
Specified Condition
B32-57 (SL1+) - B32-77 (SL1-)
20°C (68°F)
5.0 to 5.6 Ω
B32-57 (SL1+) - Body ground
20°C (68°F)
10 kΩ or higher
B32-77 (SL1-) - Body ground
20°C (68°F)
10 kΩ or higher
|
|
||||
| OK | ||
| ||
| 3. INSPECT SHIFT SOLENOID VALVE SL1 |
![]() ![]() |
Remove the shift solenoid valve SL1.
Measure the resistance of the solenoid valve.
- Standard resistance:
- 5.0 to 5.6 Ωat 20°C (68°F)
Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.
- OK:
- Valve moves and makes operating noise.
|
|
||||
| OK | ||
| ||