INSPECTION
Inspection · Vehicles built from Aug 2007
| INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY |
Measure the resistance of the oil control valve.

- Standard resistance:
Tester Connection
Specified Condition
1 (+B) - 2 (GND)
6.9 to 7.9 Ω at 20°C (68°F)
Check the operation.

Connect the battery positive (+) lead to terminal 1 and negative (-) lead to terminal 2, and check the movement of the valve.
- OK:
Condition
Specified Condition
Battery positive (+) voltage is applied
Valve moves in black arrow direction shown in illustration
Battery positive (+) voltage is cut off
Valve moves in white arrow direction shown in illustration
- NOTICE:
- If the valve cannot return properly because of foreign matter intrusion, a small leakage in the advanced direction may occur and a DTC may be output.