INSPECTION
Inspection · Vehicles built from Aug 2007
| INSPECT KNOCK SENSOR |
 |
- Measure the resistance of the sensor.
- Standard resistance:
Tester Connection
|
Condition
|
Specified Condition
|
1 (Ground) - 2 (Output)
|
20°C (68°F)
|
120 to 280 kΩ
|
If the result is not as specified, replace the knock sensor.