INSPECTION
Inspection · Vehicles built from Nov 2005
| INSPECT VACUUM REGULATING VALVE |
Inspect the VRV for an open circuit.

Measure the resistance between the terminals.
- Standard resistance:
- 11.1 to 12.5 Ω at 20°C (68°F)
Inspect the VRV operation.
Check that air flows from port E to G.

Apply battery voltage across the terminals.

Check that air flows from port E to the filter.