ON-VEHICLE INSPECTION
Inspection · Vehicles built from Nov 2005
| DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
- CAUTION:
- Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.
| INSPECT INSTRUMENT PANEL JUNCTION BLOCK |
- NOTICE:
- The circuit opening relay is built into the instrument panel junction block.
Measure the resistance between the terminals.


- Standard resistance:
Tester Connection
Specified Condition
1B-11 - 1A-8
10 kΩ or higher
1B-11 - 1A-8
Below 1 Ω
(when battery voltage is applied to terminals 1E-5 and 1D-1)
| CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |