2005-2008 RAV4 · Service Manual TRANSMISSION

P2769 Torque Converter Clutch Solenoid Circuit Low (Shift Solenoid Valve DSL)

Diagnostic trouble codes · Vehicles built from Nov 2005

Also covers:

DESCRIPTION

The shift solenoid valve DSL is turned ON and OFF by signals from the ECM to control the hydraulic pressure acting on the lock-up relay valve, which then controls operation of the lock-up clutch.
DTC No.
DTC Detection Condition
Trouble Area
P2769
ECM detects short in shift solenoid valve DSL circuit when shift solenoid valve DSL is operated (2 trip detection logic)
  1. Short in shift solenoid valve DSL circuit
  2. Shift solenoid valve DSL
  3. ECM
P2770
ECM detects open in shift solenoid valve DSL circuit when shift solenoid valve DSL is not operated (2 trip detection logic)
  1. Open in shift solenoid valve DSL circuit
  2. Shift solenoid valve DSL
  3. ECM
Fail-safe function:
If the ECM detects a malfunction, it turns the shift solenoid valve DSL OFF.

MONITOR DESCRIPTION

Torque converter lock-up is controlled by the ECM based on engine rpm, engine load, engine temperature, vehicle speed, transmission temperature, and shift position selection. The ECM determines the lock-up status of the torque converter by comparing the engine rpm (NE) to the input rpm (NT). The ECM calculates the actual transmission gear by comparing the input rpm (NT) to the output rpm (SP2). When conditions are appropriate, the ECM requests "lock-up" by applying control voltage to the shift solenoid valve DSL. When the shift solenoid valve DSL is opened, the shift solenoid valve DSL applies pressure to the lock-up relay valve and locks the torque converter clutch. If the ECM detects an open or short in the shift solenoid valve DSL circuit, the ECM interprets this as a fault in the shift solenoid valve DSL or its circuit. The ECM will illuminate the MIL and store a DTC.

WIRING DIAGRAM

C119178E11

INSPECTION PROCEDURE


1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE DSL)

  1. C129039E02
    Disconnect the B29 wire connector.

  1. Measure the resistance of the transmission wire.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    3 (DSL) - Body ground
    20°C (68°F)
    11 to 13 Ω



NG
Go to step 3
OK


2. CHECK WIRE HARNESS (TRANSMISSION WIRE - ECM)
  1. Connect the B29 wire connector.

  1. A107892E55
    Disconnect the B32 ECM connector.

  1. Measure the resistance of the wire harness side connector.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    B32-79 (DSL) - Body ground
    20°C (68°F)
    11 to 13 Ω



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

REPLACE ECM

3. INSPECT SHIFT SOLENOID VALVE DSL
A112706E01
  1. Remove the shift solenoid valve DSL.

  1. Measure the resistance between the solenoid valve terminal and solenoid valve body.

    Standard resistance:
    11 to 13 Ω at 20°C (68°F)

  1. Connect the battery's positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid body. Then check that the valve moves and makes an operating noise.

    OK:
    Valve moves and makes operating noise.



NG
REPLACE SHIFT SOLENOID VALVE DSL
OK

REPAIR OR REPLACE TRANSMISSION WIRE