B1413/13 Evaporator Temperature Sensor Circuit
Diagnostic trouble codes · Vehicles built from Nov 2005
DESCRIPTION
The No. 1 cooler thermistor (evaporator temperature sensor) is installed on the evaporator in the air conditioning unit to detect the temperature of the cooled air that has passed through the evaporator and to control the air conditioner. It sends signals to the air conditioning amplifier. The signals change in accordance with the resistance of the No. 1 cooler thermistor (evaporator temperature sensor). As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases. The air conditioning amplifier applies a voltage (5 V) to the No. 1 cooler thermistor (evaporator temperature sensor) and reads voltage changes as changes in the resistance of the No. 1 cooler thermistor (evaporator temperature sensor). This sensor is used for frost prevention.| DTC No. |
DTC Detection Condition |
Trouble Area |
| B1413/13 |
Open or short in evaporator temperature sensor circuit |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER (EVAP FIN TEMP) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch ON.
Select the item below in the Data List, and read the value displayed on the intelligent tester.
- Air conditioning amplifier:
Item
Measurement Item / Display (Range)
Normal Condition
Diagnostic Note
Evap Fin Temp
Evaporator temperature sensor / Min.: -29.7°C (-21.46°F)
Max.: 59.6°C (139.28°F)
Actual evaporator temperature is displayed
Open circuit: -29.7°C (-21.46°F)
Short circuit: 59.6°C (139.28°F)
- OK:
- The display is as specified in the normal condition column.
- Result:
Result
Proceed to
NG
A
OK (Checking from the PROBLEM SYMPTOMS TABLE)
B
OK (Checking from the DTC)
C
|
|
||||
|
|
||||
| A | |
| 2. INSPECT NO. 1 COOLER THERMISTOR (EVAPORATOR TEMPERATURE SENSOR) |
![]() ![]() |
Remove the No. 1 cooler thermistor.
Measure the resistance of the thermistor.
- Standard resistance:
Tester Connection
Condition
Specified Condition
1 - 2
-10°C (14°F)
7.30 to 9.10 kΩ
1 - 2
-5°C (23°F)
5.65 to 6.95 kΩ
1 - 2
0°C (32°F)
4.40 to 5.35 kΩ
1 - 2
5°C (41°F)
3.40 to 4.15 kΩ
1 - 2
10°C (50°F)
2.70 to 3.25 kΩ
1 - 2
15°C (59°F)
2.14 to 2.58 kΩ
1 - 2
20°C (68°F)
1.71 to 2.05 kΩ
1 - 2
25°C (77°F)
1.38 to 1.64 kΩ
1 - 2
30°C (86°F)
1.11 to 1.32 kΩ
- NOTICE:
- Touching the thermistor even slightly may change the resistance value. Be sure to hold the connector of the thermistor.
- When measuring, the thermistor temperature must be the same as the ambient temperature.
- Touching the thermistor even slightly may change the resistance value. Be sure to hold the connector of the thermistor.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).
|
|
||||
| OK | |
| 3. CHECK WIRE HARNESS (NO. 1 COOLER THERMISTOR - AIR CONDITIONING AMPLIFIER) |
![]() ![]() |
Disconnect the E38 No. 1 cooler thermistor connector.
Disconnect the E42 amplifier connector.
Measure the resistance of the wire harness side connectors.
- Standard resistance:
Tester Connection
Specified Condition
E38-1 - E42-22 (TE)
Below 1 Ω
E38-2 - E42-23 (SG-3)
Below 1 Ω
E38-1 - Body ground
1 MΩ or higher
E38-2 - Body ground
1 MΩ or higher
|
|
||||
| OK | ||
| ||


