B1411/11 Room Temperature Sensor Circuit
Diagnostic trouble codes · Vehicles built from Nov 2005
DESCRIPTION
The room temperature sensor is installed in the instrument panel to detect the room temperature and control the heater and air conditioner AUTO mode. The resistance of the room temperature sensor changes in accordance with the room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The air conditioning amplifier applies a voltage (5 V) to the room temperature sensor and reads voltage changes as changes in the resistance of the room temperature sensor.
| DTC No. |
DTC Detection Condition |
Trouble Area |
| B1411/11 |
Open or short in room temperature sensor circuit |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER (ROOM TEMP) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch ON.
Select the item below in the Data List, and read the value displayed on the intelligent tester.
- Air conditioning amplifier:
Item
Measurement Item / Display (Range)
Normal Condition
Diagnostic Note
Room Temp
Room temperature sensor / Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
Actual room temperature is displayed
Open circuit: -6.5°C (20.3°F)
Short circuit: 57.25°C (135.05°F)
- OK:
- The display is as specified in the normal condition column.
Result Result
Proceed to
NG
A
OK (Checking from the PROBLEM SYMPTOMS TABLE)
B
OK (Checking from the DTC)
C
|
|
||||
|
|
||||
| A | |
| 2. INSPECT ROOM TEMPERATURE SENSOR |
![]() ![]() |
Remove the room temperature sensor.
Measure the resistance of the sensor.
- Standard resistance:
Tester Connection
Condition
Specified Condition
1 (ST+) - 2 (ST-)
10°C (50°F)
3.00 to 3.73 kΩ
1 (ST+) - 2 (ST-)
15°C (59°F)
2.45 to 2.88 kΩ
1 (ST+) - 2 (ST-)
20°C (68°F)
1.95 to 2.30 kΩ
1 (ST+) - 2 (ST-)
25°C (77°F)
1.60 to 1.80 kΩ
1 (ST+) - 2 (ST-)
30°C (86°F)
1.28 to 1.47 kΩ
1 (ST+) - 2 (ST-)
35°C (95°F)
1.00 to 1.22 kΩ
1 (ST+) - 2 (ST-)
40°C (104°F)
0.80 to 1.00 kΩ
1 (ST+) - 2 (ST-)
45°C (113°F)
0.65 to 0.85 kΩ
1 (ST+) - 2 (ST-)
50°C (122°F)
0.50 to 0.70 kΩ
1 (ST+) - 2 (ST-)
55°C (131°F)
0.44 to 0.60 kΩ
1 (ST+) - 2 (ST-)
60°C (140°F)
0.36 to 0.50 kΩ
- NOTICE:
- Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).
|
|
||||
| OK | |
| 3. CHECK WIRE HARNESS (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER) |
![]() ![]() |
Disconnect the E24 sensor connector.
Disconnect the E41 amplifier connector.
Measure the resistance of the wire harness side connectors.
- Standard resistance:
Tester Connection
Specified Condition
E24-1 (ST+) - E41-29 (TR)
Below 1 Ω
E24-2 (ST-) - E41-34 (SG-1)
Below 1 Ω
E24-1 (ST+) - Body ground
1 MΩ or higher
E24-2 (ST-) - Body ground
1 MΩ or higher
|
|
||||
| OK | ||
| ||