DATA LIST / ACTIVE TEST
System information · Vehicles built from Aug 2007
Versions by build date: Nov 2005 – Jul 2007 from Aug 2007
| READ DATA LIST |
![]() ![]() |
- HINT:
- Using the intelligent tester's Data List allows switch, sensor, actuator and other item values to be read without removing any parts. Reading the Data List early in troubleshooting is one way to save time.
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester ON.
Read the Data List by following the prompts on the tester.
Air conditioning amplifier Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Room Temperature Sensor
Room temperature sensor /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
Actual room temperature is displayed
Open circuit: -6.5°C (20.3°F)
Short circuit: 57.25°C (135.05°F)
Ambient Temp Sensor
Ambient temperature sensor /
Min.: -23.3°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature is displayed
Open circuit: -23.3°C (-9.94°F)
Short circuit: 65.95°C (150.71°F)
Adjusted Ambient Temp
Adjusted ambient temperature /
Min.: -30.8°C (-23.44°F)
Max.: 50.8°C (123.44°F)
-
-
Evaporator Fin Thermistor
Evaporator temperature sensor /
Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature is displayed
Open circuit: -29.7°C (-21.46°F)
Short circuit: 59.55°C (139.19°F)
Solar Sensor (D side)
Driver side solar sensor /
Min.: 0, Max.: 255
Driver side solar sensor value increases as brightness increases
-
Solar Sensor (P side)
Passenger side solar sensor /
Min.: 0, Max.: 255
Passenger side solar sensor value increases as brightness increases
-
Engine Coolant Temp
Engine coolant temperature /
Min.: 1.3°C (34.34°F)
Max.: 90.55°C (194.99°F)
Actual engine coolant temperature is displayed after engine warmed up
-
Set Temperature (D side)
Driver side set temperature /
Min.: 0°C (32°F)
Max.: 30°C (54°F)
Driver side actual set temperature is displayed
-
Set Temperature (P side)
Passenger side set temperature /
Min.: 0°C (32°F)
Max.: 30°C (54°F)
Passenger side actual set temperature is displayed
-
Blower Motor Speed Level
Blower motor speed level /
Min.: 0 level, Max.: 31 level
Increases 0 to 31 as blower motor speed increases
-
Regulator Pressure Sensor
Regulator pressure sensor /
Min.: -0.45668 MPaG
Max.: 3.29437 MPaG
Actual regulator pressure is displayed
-
Regulator Control Current
Regulator control current /
Min.: 0 A
Max.: 0.997 A
Value changes between 0 A and 0.997 A in accordance with compressor operation
-
Air Mix Servo Targ Pulse (D)
Driver side air mix servo motor target pulse /
Min.: 0, Max.: 255
LHD:
MAX. COLD: 92 (pulse)
MAX. HOT: 5 (pulse)
RHD:
MAX. COLD: 6 (pulse)
MAX. HOT: 93 (pulse)
-
Air Mix Servo Targ Pulse (P)
Passenger side air mix servo motor target pulse /
Min.: 0, Max.: 255
LHD:
MAX. COLD: 6 (pulse)
MAX. HOT: 93 (pulse)
RHD:
MAX. COLD: 92 (pulse)
MAX. HOT: 5 (pulse)
-
Air Outlet Servo Pulse (D)
Air outlet servo motor target /
Min.: 0, Max.: 255
FACE: 47 (pulse)
B/L: 37 (pulse)
FOOT: 17 (pulse)
FOOT/DEF: 9 (pulse)
DEF: 5 (pulse)
-
Air Inlet Damper Targ Pulse
Air inlet damper target pulse /
Min.: 0, Max.: 255
LHD:
RECIRCULATION: 19 (pulse)
FRESH: 7 (pulse)
RHD:
RECIRCULATION: 7 (pulse)
FRESH: 25 (pulse)
-
Electric Heater Count
Electric (PTC) heater count /
Min.: 0
Max.: 3
Actual number of the heater elements to be heated is displayed
-
Shift Set Temperature
Shift set temperature / +2 C, +1 C, NORMAL, -1 C, -2 C
Customized value displayed
-
Air Inlet Mode
Air inlet mode /
AUTO, MANUAL
Customized value displayed
-
Compressor Mode
Compressor mode /
AUTO, MANUAL
Customized value displayed
-
Compressor/DEF Mode
Compressor / DEF Mode /
LINK, NORMAL
Customized value displayed
-
Evaporator Control
Evaporator Control /
AUTO, MANUAL
Customized value displayed
-
Foot/DEF Auto Mode
Foot / DEF auto mode /
ON, OFF
Customized value displayed
-
Foot/DEF Auto Blow Up
Foot / DEF automatic blow up function /
ON, OFF
Customized value displayed
-
Ambient Temperature Shift
Ambient temperature shift / +3C, +2C, +1C, Normal, -1C, -2C, -3C
Customized value displayed
-
Number of Trouble Codes
Number of trouble codes /
Min.: 0, Max.: 255
Number of DTCs displayed
-
| PERFORM ACTIVE TEST |
- HINT:
- Performing the intelligent tester's Active Test allows relays, the VSV, actuators and other items to be operated without removing any parts. Performing the Active Test early in troubleshooting is one way to save time. The Data List can be displayed in the Active Test.
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester ON.
Perform the Active Test by following the prompts on the tester.
Air conditioning amplifier Tester Display
Test Part
Control Range
Diagnostic Note
Blower Motor
Blower motor
Min.: 0, Max.: 31
-
Magnetic Clutch Relay
Magnetic clutch relay
OFF, ON
-
Defogger Relay (Rear)
Defogger relay (Rear)
OFF, ON
-
Electric Heater 1
PTC heater No. 1 relay
OFF, ON
-
Electric Heater 2
PTC heater No. 2 relay
OFF, ON
-
Air Mix Servo Targ Pulse (D)
Air mix servo motor pulse
Min.: 0, Max.: 255
-
Air Mix Servo Targ Pulse (P)
Air mix servo motor pulse (P side)
Min.: 0, Max.: 255
-
Air Outlet Servo Pulse (D)
Air outlet servo motor pulse
Min.: 0, Max.: 255
-
Air Inlet Damper Targ Pulse
Air inlet damper target pulse
Min.: 0, Max.: 255
-