2005-2008 RAV4 · Service Manual HEATER & AIR CONDITIONING SYSTEM

INSPECTION

Inspection · Vehicles built from Nov 2005


INSPECT EVAPORATOR TEMPERATURE SENSOR

  1. E126546E01
    Measure the resistance of the sensor.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    -10°C (14°F)
    7.30 to 9.10 kΩ
    1 - 2
    -5°C (23°F)
    5.65 to 6.95 kΩ
    1 - 2
    0°C (32°F)
    4.40 to 5.35 kΩ
    1 - 2
    5°C (41°F)
    3.40 to 4.15 kΩ
    1 - 2
    10°C (50°F)
    2.70 to 3.25 kΩ
    1 - 2
    15°C (59°F)
    2.14 to 2.58 kΩ
    1 - 2
    20°C (68°F)
    1.71 to 2.05 kΩ
    1 - 2
    25°C (77°F)
    1.38 to 1.64 kΩ
    1 - 2
    30°C (86°F)
    1.11 to 1.32 kΩ

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    1. When measuring, the sensor temperature must be almost the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).
    If the result is not as specified, replace the sensor.

← REMOVAL (from Jan 2007)INSTALLATION (Nov 2005 – Dec 2006) →