SERVICE DATA
Specifications · Vehicles built from Nov 2005
| Condition |
Specified Condition |
|
| Valve opening temperature |
80 to 84°C (176 to 183°F) |
|
| Valve lift |
at 95°C (203°F) |
10 mm (0.39 in.) or more |
| Indication Mark |
Motor Type |
Condition |
Specified Condition |
| A |
80 W |
at 20°C (68°F) |
5.8 to 7.8 A |
| B, C |
160 W |
at 20°C (68°F) |
11.7 to 14.7 A |
| Indication Mark |
Motor Type |
Condition |
Specified Condition |
| A |
80 W |
at 20°C (68°F) |
5.8 to 7.8 A |
| B |
120 W |
at 20°C (68°F) |
8.4 to 10.4 A |
| C |
160 W |
at 20°C (68°F) |
11.7 to 14.7 A |
| Tester Connection |
Specified Condition |
| 3 - 5 |
10 Ω or higher |
| 3 - 5 |
Below 1 Ω (When battery voltage is applied to terminals 1 and 2) |
| Tester Connection |
Specified Condition |
| 3 - 4 |
Below 1 Ω |
| 3 - 5 |
10 Ω or higher |
| 3 - 4 |
10 Ω or higher (When battery voltage is applied to terminals 1 and 2) |
| 3 - 5 |
Below 1 Ω (When battery voltage is applied to terminals 1 and 2) |
| Tester Connection |
Specified Condition |
| 3 - 5 |
10 Ω or higher |
| 3 - 5 |
Below 1 Ω (When battery voltage is applied to terminals 1 and 2) |
| Item |
Specified Condition |
| Standard value (for brand-new cap) |
93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi) |
| Minimum standard value (after using cap) |
78.5 kPa (0.8 kgf/cm2, 11.4 psi) |