SERVICE DATA
Specifications · Vehicles built from Jan 2007
Versions by build date: Nov 2005 – Dec 2006 from Jan 2007
| Turbocharging pressure |
Standard |
53 to 61 kPa (0.54 to 0.6 kgf/cm2, 7.7 to 8.8 psi) |
| Actuator rod clearance |
Stopped |
About 5.5 mm (0.217 in.) |
| Idling |
0.8 mm (0.031 in.) |
|
| Actuator pressure |
Stopped |
0 kPa (0 kgf/cm2, 0 psi) |
| Idling |
42.2 kPa (0.43 kgf/cm2, 6.1 psi) |
|
| Vacuum regulating valve |
resistance |
11.1 to 12.5 Ω at 20°C (68°F) |
| Axial play |
Maximum |
0.08 mm (0.0031 in.) |
| Radial play |
Maximum |
0.110 mm (0.0043 in.) |