2005-2008 RAV4 · Service Manual BODY ELECTRICAL

ON-VEHICLE INSPECTION

Inspection · Vehicles built from Nov 2005


INSPECT TURN SIGNAL FLASHER CIRCUIT (for LHD)

  1. I042805E04
    Check the power source circuit and ground circuit.

    1. Remove the turn signal flasher relay from the instrument panel junction block.

    2. Measure the voltage and resistance of the instrument panel junction block.

      Standard voltage:
      Tester Connection
      Condition
      Specified Condition
      Turn signal flasher relay terminal 1 (IG) - Body ground
      Ignition switch off
      Below 1 V
      Turn signal flasher relay terminal 1 (IG) - Body ground
      Ignition switch on (IG)
      10 to 14 V
      Turn signal flasher relay terminal 4 (+B) - Body ground
      Always
      10 to 14 V

      Standard resistance:
      Tester Connection
      Specified Condition
      Turn signal flasher relay terminal 7 (GND) - Body ground
      Below 1 Ω

  1. Check the output operation signal.

    1. Install the turn signal flasher relay onto the instrument panel junction block.

      I042806E03

    2. Measure the voltage of the instrument panel junction block.

      Standard voltage:
      Tester Connection
      Condition
      Specified Condition
      IA-27 (LL) - Body ground
      Hazard warning switch OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      IA-27 (LL) - Body ground
      Turn signal switch (left turn) OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      IA-28 (LR) - Body ground
      Hazard warning switch OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      IA-28 (LR) - Body ground
      Turn signal switch (right turn) OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      IB-14 (LL) - Body ground
      Hazard warning switch OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      IB-14 (LL) - Body ground
      Turn signal switch (left turn) OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      IB-31 (LR) - Body ground
      Hazard warning switch OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      IB-31 (LR) - Body ground
      Turn signal switch (right turn) OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      IS-11 (EL) - Body ground
      Turn signal switch (left turn) OFF → ON
      10 to 14 V → 0 V
      IS-12 (ER) - Body ground
      Turn signal switch (right turn) OFF → ON
      10 to 14 V → 0 V
      IS-13 (LL) - Body ground
      Hazard warning switch OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      IS-13 (LL) - Body ground
      Turn signal switch (left turn) OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      IS-16 (LR) - Body ground
      Hazard warning switch OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      IS-16 (LR) - Body ground
      Turn signal switch (right turn) OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      IS-17 (EHW) - Body ground
      Hazard warning switch OFF → ON
      10 to 14 V → 0 V

      If the result is not as specified, replace the turn signal flasher relay.


INSPECT TURN SIGNAL FLASHER CIRCUIT (for RHD)

E068703E10
  1. Check the power source circuit and ground circuit.

    1. Remove the turn signal flasher assembly.

    2. Measure the voltage and resistance of the wire harness side connector.

      Standard Voltage:
      Tester Connection
      Condition
      Specified Condition
      E81-1 (IG) - Body ground
      Ignition switch off
      0 V
      E81-1 (IG) - Body ground
      Ignition switch on (IG)
      10 to 14 V
      E81-4 (+B) - Body ground
      Always
      10 to 14 V

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      E81-7 (GND) - Body ground
      Always
      Below 1 Ω

  1. Check the output operation signal.

    1. E101506E04
      Install the turn signal flasher relay.

    2. Measure the voltage of the turn signal flasher relay.

      Standard:
      Tester Connection
      Condition
      Specified Condition
      2 (LR) - Body ground
      Hazard warning switch OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      2 (LR) - Body ground
      Turn signal switch (right turn) OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      3 (LL) - Body ground
      Hazard warning switch OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      3 (LL) - Body ground
      Turn signal switch (left turn) OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      5 (EL) - Body ground
      Turn signal switch (left turn) OFF → ON
      10 to 14 V → 0 V
      6 (ER) - Body ground
      Turn signal switch (right turn) OFF → ON
      10 to 14 V → 0 V
      8 (HAZ) - Body ground
      Hazard warning switch OFF → ON
      10 to 14 V → 0 V

      If the result is not as specified, replace the turn signal flasher relay.

← INSTALLATION (from Nov 2005)COMPONENTS (from Aug 2008) →