ON-VEHICLE INSPECTION
Inspection · Vehicles built from Nov 2005
| INSPECT TURN SIGNAL FLASHER CIRCUIT (for LHD) |
Check the power source circuit and ground circuit.

Remove the turn signal flasher relay from the instrument panel junction block.
Measure the voltage and resistance of the instrument panel junction block.
- Standard voltage:
Tester Connection
Condition
Specified Condition
Turn signal flasher relay terminal 1 (IG) - Body ground
Ignition switch off
Below 1 V
Turn signal flasher relay terminal 1 (IG) - Body ground
Ignition switch on (IG)
10 to 14 V
Turn signal flasher relay terminal 4 (+B) - Body ground
Always
10 to 14 V
- Standard resistance:
Tester Connection
Specified Condition
Turn signal flasher relay terminal 7 (GND) - Body ground
Below 1 Ω
Check the output operation signal.
Install the turn signal flasher relay onto the instrument panel junction block.


Measure the voltage of the instrument panel junction block.
- Standard voltage:
Tester Connection
Condition
Specified Condition
IA-27 (LL) - Body ground
Hazard warning switch OFF → ON
0 V → 10 to 14 V (60 to 120 times per minute)
IA-27 (LL) - Body ground
Turn signal switch (left turn) OFF → ON
0 V → 10 to 14 V (60 to 120 times per minute)
IA-28 (LR) - Body ground
Hazard warning switch OFF → ON
0 V → 10 to 14 V (60 to 120 times per minute)
IA-28 (LR) - Body ground
Turn signal switch (right turn) OFF → ON
0 V → 10 to 14 V (60 to 120 times per minute)
IB-14 (LL) - Body ground
Hazard warning switch OFF → ON
0 V → 10 to 14 V (60 to 120 times per minute)
IB-14 (LL) - Body ground
Turn signal switch (left turn) OFF → ON
0 V → 10 to 14 V (60 to 120 times per minute)
IB-31 (LR) - Body ground
Hazard warning switch OFF → ON
0 V → 10 to 14 V (60 to 120 times per minute)
IB-31 (LR) - Body ground
Turn signal switch (right turn) OFF → ON
0 V → 10 to 14 V (60 to 120 times per minute)
IS-11 (EL) - Body ground
Turn signal switch (left turn) OFF → ON
10 to 14 V → 0 V
IS-12 (ER) - Body ground
Turn signal switch (right turn) OFF → ON
10 to 14 V → 0 V
IS-13 (LL) - Body ground
Hazard warning switch OFF → ON
0 V → 10 to 14 V (60 to 120 times per minute)
IS-13 (LL) - Body ground
Turn signal switch (left turn) OFF → ON
0 V → 10 to 14 V (60 to 120 times per minute)
IS-16 (LR) - Body ground
Hazard warning switch OFF → ON
0 V → 10 to 14 V (60 to 120 times per minute)
IS-16 (LR) - Body ground
Turn signal switch (right turn) OFF → ON
0 V → 10 to 14 V (60 to 120 times per minute)
IS-17 (EHW) - Body ground
Hazard warning switch OFF → ON
10 to 14 V → 0 V
| INSPECT TURN SIGNAL FLASHER CIRCUIT (for RHD) |
![]() ![]() |
Check the power source circuit and ground circuit.
Remove the turn signal flasher assembly.
Measure the voltage and resistance of the wire harness side connector.
- Standard Voltage:
Tester Connection
Condition
Specified Condition
E81-1 (IG) - Body ground
Ignition switch off
0 V
E81-1 (IG) - Body ground
Ignition switch on (IG)
10 to 14 V
E81-4 (+B) - Body ground
Always
10 to 14 V
- Standard Resistance:
Tester Connection
Condition
Specified Condition
E81-7 (GND) - Body ground
Always
Below 1 Ω
Check the output operation signal.
Install the turn signal flasher relay.

Measure the voltage of the turn signal flasher relay.
- Standard:
Tester Connection
Condition
Specified Condition
2 (LR) - Body ground
Hazard warning switch OFF → ON
0 V → 10 to 14 V (60 to 120 times per minute)
2 (LR) - Body ground
Turn signal switch (right turn) OFF → ON
0 V → 10 to 14 V (60 to 120 times per minute)
3 (LL) - Body ground
Hazard warning switch OFF → ON
0 V → 10 to 14 V (60 to 120 times per minute)
3 (LL) - Body ground
Turn signal switch (left turn) OFF → ON
0 V → 10 to 14 V (60 to 120 times per minute)
5 (EL) - Body ground
Turn signal switch (left turn) OFF → ON
10 to 14 V → 0 V
6 (ER) - Body ground
Turn signal switch (right turn) OFF → ON
10 to 14 V → 0 V
8 (HAZ) - Body ground
Hazard warning switch OFF → ON
10 to 14 V → 0 V