SERVICE DATA
Specifications · Vehicles built from Aug 2007
| Condition |
Specified Condition |
| Standard valve opening temperature |
80 to 84°C (176 to 183°F) |
| Standard valve lift |
10 mm (0.39 in.) or more at 95°C (203°F) |
| Item |
Motor Type |
Condition |
Specified Condition |
| No. 1 cooling fan motor |
240 W |
at 20°C (68°F) |
18.0 to 22.0 A |
| No. 2 cooling fan motor |
240 W |
at 20°C (68°F) |
18.0 to 22.0 A |
| Item |
Tester Connection |
Condition |
Specified Condition |
| Cooling fan ECU |
A64-3 - Body ground |
Ignition switch ON |
11 to 14 V |
| A65-3 - Body ground |
Ignition switch ON |
11 to 14 V |
|
| A64-1 - Body ground |
Always |
Below 1 Ω |
|
| A65-1 - Body ground |
Always |
Below 1 Ω |
| Item |
Tester Connection |
Specified Condition |
| No. 1 fan relay |
3 - 5 |
10 kΩ or higher |
| 3 - 5 |
Below 1 Ω (when battery voltage is applied to terminals 1 and 2) |
|
| No. 2 fan relay |
3 - 5 |
10 kΩ or higher |
| 3 - 5 |
Below 1 Ω (when battery voltage is applied to terminals 1 and 2) |
| Item |
Tester Connection |
Specified Condition |
| Radiator reservoir cap |
For brand-new cap |
93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi) |
| For used cap |
78.5 kPa (0.8 kgf/cm2, 11.4 psi) |