AIRBAG SYSTEM > SRS Warning Light Remains ON |

| 1.CHECK BATTERY |
Measure the voltage of the battery.
|
| ||||
| OK | |
| 2.CHECK CONNECTOR |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Check that the connectors are properly connected to the center airbag sensor and combination meter.
|
| ||||
| OK | |
| 3.CHECK WIRE HARNESS (SOURCE VOLTAGE OF CENTER AIRBAG SENSOR ASSEMBLY) |
![]() |
Disconnect the E49 connector from the center airbag sensor.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch on (IG).
Operate all components of the electrical system (defogger, wipers, headlight, heater blower, etc.).
Measure the voltage of the wire harness side connector.
| Tester Connection | Specified Condition |
| E49-21 (IG2) - Body ground | 10 to 14 V |
Turn the ignition switch off.
Measure the resistance of the wire harness side connector.
| Tester Connection | Specified Condition |
| E49-25 (E1) - Body ground | Below 1 Ω |
| E49-26 (E2) - Body ground | Below 1 Ω |
|
| ||||
| OK | |
| 4.CHECK WIRE HARNESS (SOURCE VOLTAGE OF COMBINATION METER) |
![]() |
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect the E22 connector from the combination meter.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch on (IG).
Measure the voltage of the wire harness side connector.
| Tester Connection | Condition | Specified Condition |
| E22-21 (IG+) - Body ground | Ignition switch on (IG) | 10 to 14 V |
| E22-22 (B) - Body ground | Always | 10 to 14 V |
Turn the ignition switch off.
Measure the resistance of the wire harness side connector.
| Tester Connection | Specified Condition |
| E22-33 (ET) - Body ground | Below 1 Ω |
|
| ||||
| OK | |
| 5.CHECK SRS WARNING LIGHT |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Connect the E22 connector to the combination meter.
Connect the cable to the negative (-) terminal, and wait for at least 2 seconds.
Turn the ignition switch on (IG).
Check the SRS warning light condition.
|
| ||||
| OK | ||
| ||