Home › BODY ELECTRICAL › LIGHTING › HAZARD WARNING SWITCH

HAZARD WARNING SWITCH > INSPECTION

for Preparation Click here



1. INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY


    E107908E05
  1. Measure the resistance of the switch.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    4 (TB) - 1 (E)
    OFF (Not pushed)
    10 kΩ or higher
    4 (TB) - 1 (E)
    ON (Pushed)
    Below 23.4 Ω

    If the result is not as specified, replace the switch assembly.

  1. Inspect the switch illumination.

    1. Connect the battery positive (+) lead to terminal 3 (ILL+) and the negative (-) lead to terminal 2 (ILL-), then check that the light comes on.

      OK:
      LED comes on.

      If the result is not as specified, replace the light.