Home › TRANSMISSION ยท EA64 MANUAL TRANSAXLE › BACK-UP LIGHT SWITCH

BACK-UP LIGHT SWITCH > INSTALLATION

for Preparation Click here



1. INSTALL BACK-UP LIGHT SWITCH ASSEMBLY


    C112472E01
  1. Using SST, install the back-up light switch with a new gasket onto the transaxle.

    SST
    09817-16011  

    Torque:
    40 N*m{ 410 kgf*cm , 30 ft.*lbf }



    C112470
  1. Connect the back-up light switch connector.



2. INSTALL ENGINE UNDER COVER REAR LH
  1. Install the under cover with the 2 clips.