Home › ENGINE ยท 2AD-FTV › CHARGING › CHARGING SYSTEM

CHARGING SYSTEM > PRECAUTION

for Preparation Click here



1.Check that the battery cables are connected to the correct terminals.

2.Disconnect the battery cables when the battery is given a quick charge.

3.Do not perform tests with a high voltage insulation resistance tester.

4.Never disconnect the battery while the engine is running.

5.Check that the charging cable is tightened on terminal B of the generator and the engine room relay block.

6.EXPRESSIONS OF IGNITION SWITCH

HINT:
The type of ignition switch used on this model differs according to the specifications of the vehicle. The expressions listed in the table below are used in this section.

Expression
Ignition Switch (position)
Engine Switch (condition)
Ignition Switch off
Off
Off
Ignition Switch ON
ON
On (IG)
Ignition Switch ACC
ACC
On (ACC)
Engine Start
START
Start