Home › ENGINE · 2AD-FTV › CHARGING › GENERATOR

GENERATOR > INSPECTION

for Preparation Click here



1. INSPECT GENERATOR BRUSH HOLDER ASSEMBLY


    B016374
  1. Using a vernier caliper, measure the brush length.

    Standard exposed length:
    9.5 to 11.5 mm (0.374 to 0.453 in.)

    Minimum exposed length:
    4.5 mm (0.177 in.)

    If the brush length is less than the minimum, replace the generator brush holder assembly.



2. INSPECT GENERATOR ROTOR ASSEMBLY


    A196808E01
  1. Check the rotor for an open circuit.

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      Slip ring - Slip ring
      20°C (68°F)
      1.5 to 1.9 Ω

      Text in Illustration 
      *1
      Slip Ring
      If the result is not as specified, replace the generator rotor assembly.



    A196809E01
  1. Check if the rotor is grounded.

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      Slip ring - Rotor
      Always
      10 kΩ or higher

      Text in Illustration 
      *1
      Slip Ring
      *2
      Rotor Core
      If the result is not as specified, replace the generator rotor assembly.

  1. Check that the slip rings are not rough or scored.
    If rough or scored, replace the generator rotor assembly.



    A097470E02
  1. Using a vernier caliper, measure the diameter of the slip rings.

    Standard diameter:
    14.2 to 14.4 mm (0.559 to 0.567 in.)

    Minimum diameter:
    14.0 mm (0.551 in.)

    If the diameter is less than the minimum, replace the generator rotor assembly.



3. INSPECT GENERATOR ROTOR BEARING


    A196744
  1. Check that the bearing is not rough or worn, and that it rotates smoothly.
    If the result is not as specified, replace the generator rotor assembly.



4. INSPECT GENERATOR DRIVE END FRAME BEARING


    A196743
  1. Check that the bearing is not rough or worn, and that it rotates smoothly.
    If the bearing does not rotate smoothly, replace the generator drive end frame bearing.



5. INSPECT GENERATOR PULLEY


    A196799E03
  1. Hold the center of the generator pulley, and check that the outer ring turns counterclockwise and does not turn clockwise.
    If the result is not as specified, replace the generator pulley.
    Text in Illustration 
    *1
    Free
    *2
    Lock