AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) > DATA LIST / ACTIVE TEST |
| DATA LIST |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Data List.
According to the display on the intelligent tester, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Ambient Temp Sensor | Ambient temperature sensor / Min.: -23.3°C (-9.94°F) Max.: 65.95°C (150.71°F) | Actual ambient temperature displayed | Open in the circuit: -23.3°C (-9.94°F) Short in the circuit: 65.95°C (150.71°F) |
| Engine Coolant Temp | Engine coolant temperature / Min.: 1.3°C (34.34°F) Max.: 90.55°C (194.99°F) | Actual engine coolant temperature displayed after engine warmed up | - |
| Adjusted Ambient Temp | Adjusted ambient temperature / Min.: -30.8°C (-23.44°F) Max.: 50.8°C (123.44°F) | - | - |
| Evaporator Fin Thermistor | Evaporator temperature sensor / Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) | Actual evaporator temperature displayed | Open in the circuit: -29.7°C (-21.46°F) Short in the circuit: 59.55°C (139.19°F) |
| Regulator Pressure Sensor | Regulator pressure sensor / Min.: -0.45668 MPaG Max.: 3.29437 MPaG | Actual regulator pressure displayed | - |
| Regulator Control Current | Compressor assembly with pulley / Min.: 0 A Max.: 0.997 A | Value changes between 0 A and 0.997 A in accordance with compressor operation | - |
| Electric Heater Count | Electric (PTC) heater count/ Min.: 0 Max.: 3 | Actual number of the heater elements to be heated is displayed | - |
| Number of Trouble Codes | Number of trouble codes / Min.: 0, Max.: 255 | Number of DTCs displayed | - |
| ACTIVE TEST |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Active Test.
According to the display on the intelligent tester, perform the Active Test.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Electric Heater 1 | PTC heater No. 1 relay | ON or OFF | - |
| Electric Heater 2 | PTC heater No. 2 relay | ON or OFF | - |
| Electric Heater 3* | PTC heater No. 3 relay | ON or OFF | - |