DTC    B1411/11    Room Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The cooler thermistor (room temperature sensor) is installed in the instrument panel to detect the room temperature and control the heater and air conditioning auto mode. The resistance of the cooler thermistor (room temperature sensor) changes in accordance with the room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies a voltage (5 V) to the cooler thermistor (room temperature sensor) and reads voltage changes as changes in the resistance of the cooler thermistor (room temperature sensor).

DTC Code
DTC Detection Condition
Trouble Area
B1411/11
An open or short in the room temperature sensor circuit
  1. Cooler thermistor (room temperature sensor)
  2. Harness or connector between room temperature sensor and air conditioning amplifier assembly
  3. Air conditioning amplifier assembly

WIRING DIAGRAM


E115796E19


INSPECTION PROCEDURE

1.READ VALUE USING INTELLIGENT TESTER (ROOM TEMPERATURE SENSOR)
  1. Use the Data List to check if the room temperature sensor is functioning properly.

    Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Room Temperature Sensor
    Room temperature sensor /
    Min.: -6.5°C (20.3°F)
    Max.: 57.25°C (135.05°F)
    Actual room temperature for front seat displayed
    Open in the circuit: -6.5°C (20.3°F)
    Short in the circuit: 57.25°C (135.05°F)

    OK:
    The display is as specified in the normal condition column.

    Result 
    Result
    Proceed to
    NG
    A
    OK (Checking from the PROBLEM SYMPTOMS TABLE)
    B
    OK (Checking from the DTC)
    C



B
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY
A


2.INSPECT COOLER THERMISTOR (ROOM TEMPERATURE SENSOR)
E117004E26
  1. Remove the room temperature sensor.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (ST+) - 2 (ST-)
    10°C (50°F)
    3.00 to 3.73 kΩ
    1 (ST+) - 2 (ST-)
    15°C (59°F)
    2.45 to 2.88 kΩ
    1 (ST+) - 2 (ST-)
    20°C (68°F)
    1.95 to 2.30 kΩ
    1 (ST+) - 2 (ST-)
    25°C (77°F)
    1.60 to 1.80 kΩ
    1 (ST+) - 2 (ST-)
    30°C (86°F)
    1.28 to 1.47 kΩ
    1 (ST+) - 2 (ST-)
    35°C (95°F)
    1.00 to 1.22 kΩ
    1 (ST+) - 2 (ST-)
    40°C (104°F)
    0.80 to 1.00 kΩ
    1 (ST+) - 2 (ST-)
    45°C (113°F)
    0.65 to 0.85 kΩ
    1 (ST+) - 2 (ST-)
    50°C (122°F)
    0.50 to 0.70 kΩ
    1 (ST+) - 2 (ST-)
    55°C (131°F)
    0.44 to 0.60 kΩ
    1 (ST+) - 2 (ST-)
    60°C (140°F)
    0.36 to 0.50 kΩ

    HINT:
    As the temperature increases, the resistance decreases (Refer to the graph).

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.



NG
REPLACE COOLER THERMISTOR (ROOM TEMPERATURE SENSOR)
OK


3.CHECK HARNESS AND CONNECTOR (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)
E115797E12
  1. Disconnect the E24 sensor connector.

  1. Disconnect the E41 amplifier connector.

  1. Measure the according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    E24-1 (ST+) - E41-29 (TR)
    Always
    Below 1 Ω
    E24-2 (ST-) - E41-34 (SG-1)
    Always
    Below 1 Ω
    E24-1 (ST+) - Body ground
    Always
    10 kΩ or higher
    E24-2 (ST-) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY