DTC B1412/12 Ambient Temperature Sensor Circuit |
| DTC Code | DTC Detection Condition | Trouble Area |
| B1412/12 | An open or short in the ambient temperature sensor circuit |
|

| 1.READ VALUE USING INTELLIGENT TESTER (AMBIENT TEMPERATURE SENSOR) |
Use the Data List to check if the ambient temperature sensor is functioning properly.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Ambient Temp Sensor | Ambient temperature sensor / Min.: -23.3°C (-9.94°F) Max.: 65.95°C (150.71°F) | Actual ambient temperature displayed | Open in the circuit: -23.3°C (-9.94°F) Short in the circuit: 65.95°C (150.71°F) |
| Result | Proceed to |
| NG | A |
| OK (Checking from the PROBLEM SYMPTOMS TABLE) | B |
| OK (Checking from the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT COOLER THERMISTOR (AMBIENT TEMPERATURE SENSOR) |
![]() |
Remove the ambient temperature sensor.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 (OT-) - 2 (OT+) | 10°C (50°F) | 3.00 to 3.73 kΩ |
| 1 (OT-) - 2 (OT+) | 15°C (50°F) | 2.45 to 2.88 kΩ |
| 1 (OT-) - 2 (OT+) | 20°C (68°F) | 1.95 to 2.30 kΩ |
| 1 (OT-) - 2 (OT+) | 25°C (77°F) | 1.60 to 1.80 kΩ |
| 1 (OT-) - 2 (OT+) | 30°C (86°F) | 1.28 to 1.47 kΩ |
| 1 (OT-) - 2 (OT+) | 35°C (95°F) | 1.00 to 1.22 kΩ |
| 1 (OT-) - 2 (OT+) | 40°C (104°F) | 0.80 to 1.00 kΩ |
| 1 (OT-) - 2 (OT+) | 45°C (113°F) | 0.65 to 0.85 kΩ |
| 1 (OT-) - 2 (OT+) | 50°C (122°F) | 0.50 to 0.70 kΩ |
| 1 (OT-) - 2 (OT+) | 55°C (131°F) | 0.44 to 0.60 kΩ |
| 1 (OT-) - 2 (OT+) | 60°C (140°F) | 0.36 to 0.50 kΩ |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - COMBINATION METER) |
![]() |
Disconnect the A24 sensor connector.
Disconnect the E22 meter connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A24-2 (OT+) - E22-28 (TEMP) | Always | Below 1 Ω |
| A24-1 (OT-) - E22-11 (TX1+) | Always | Below 1 Ω |
| A24-2 (OT+) - Body ground | Always | 10 kΩ or higher |
| A24-1 (OT-) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||