DTC    B1412/12    Ambient Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The cooler thermistor (ambient temperature sensor) is installed in the front part of the condenser to detect the ambient temperature and control the air conditioning auto mode. The sensor is connected to the combination meter assembly and detects fluctuations in the ambient temperature. This data is used for controlling the room temperature. The sensor sends a signal to the air conditioning amplifier assembly via the combination meter assembly. The resistance of the cooler thermistor (ambient temperature sensor) changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies a voltage (5 V) to the cooler thermistor (ambient temperature sensor) and reads voltage changes as changes in the resistance of the cooler thermistor (ambient temperature sensor). The combination meter assembly sends the read signal to the air conditioning amplifier assembly via CAN communication.

DTC Code
DTC Detection Condition
Trouble Area
B1412/12
An open or short in the ambient temperature sensor circuit
  1. Cooler thermistor (Ambient temperature sensor)
  2. Harness or connector between ambient temperature sensor and combination meter assembly
  3. Combination meter assembly
  4. Air conditioning amplifier assembly
  5. CAN communication line

WIRING DIAGRAM


E115798E09


INSPECTION PROCEDURE

1.READ VALUE USING INTELLIGENT TESTER (AMBIENT TEMPERATURE SENSOR)
  1. Use the Data List to check if the ambient temperature sensor is functioning properly.

    Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Ambient Temp Sensor
    Ambient temperature sensor /
    Min.: -23.3°C (-9.94°F)
    Max.: 65.95°C (150.71°F)
    Actual ambient temperature displayed
    Open in the circuit: -23.3°C (-9.94°F)
    Short in the circuit: 65.95°C (150.71°F)

    OK:
    The display is as specified in the normal condition column.

    Result 
    Result
    Proceed to
    NG
    A
    OK (Checking from the PROBLEM SYMPTOMS TABLE)
    B
    OK (Checking from the DTC)
    C



B
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY
A


2.INSPECT COOLER THERMISTOR (AMBIENT TEMPERATURE SENSOR)
E114516E21
  1. Remove the ambient temperature sensor.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (OT-) - 2 (OT+)
    10°C (50°F)
    3.00 to 3.73 kΩ
    1 (OT-) - 2 (OT+)
    15°C (50°F)
    2.45 to 2.88 kΩ
    1 (OT-) - 2 (OT+)
    20°C (68°F)
    1.95 to 2.30 kΩ
    1 (OT-) - 2 (OT+)
    25°C (77°F)
    1.60 to 1.80 kΩ
    1 (OT-) - 2 (OT+)
    30°C (86°F)
    1.28 to 1.47 kΩ
    1 (OT-) - 2 (OT+)
    35°C (95°F)
    1.00 to 1.22 kΩ
    1 (OT-) - 2 (OT+)
    40°C (104°F)
    0.80 to 1.00 kΩ
    1 (OT-) - 2 (OT+)
    45°C (113°F)
    0.65 to 0.85 kΩ
    1 (OT-) - 2 (OT+)
    50°C (122°F)
    0.50 to 0.70 kΩ
    1 (OT-) - 2 (OT+)
    55°C (131°F)
    0.44 to 0.60 kΩ
    1 (OT-) - 2 (OT+)
    60°C (140°F)
    0.36 to 0.50 kΩ

    HINT:
    As the temperature increases, the resistance decreases (Refer to the graph).

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.



NG
REPLACE COOLER THERMISTOR (AMBIENT TEMPERATURE SENSOR)
OK


3.CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - COMBINATION METER)
E180818E01
  1. Disconnect the A24 sensor connector.

  1. Disconnect the E22 meter connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A24-2 (OT+) - E22-28 (TEMP)
    Always
    Below 1 Ω
    A24-1 (OT-) - E22-11 (TX1+)
    Always
    Below 1 Ω
    A24-2 (OT+) - Body ground
    Always
    10 kΩ or higher
    A24-1 (OT-) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE COMBINATION METER ASSEMBLY