AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > Blower Motor Circuit |


| 1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (BLOWER MOTOR) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch ON.
Select the item below in the Active Test, and then check that the blower motor operates.
| Item | Test Details / Display | Diagnostic Note |
| Blower Motor | Blower motor / Min.: 0, Max.: 31 | - |
| Result | Proceed to |
| NG (blower motor does not operate) | A |
| NG (blower motor operates but does not change speed) | B |
| OK | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT FUSE (HTR) |
Remove the HTR H-fuse from the engine room No. 2 relay block.
Measure the resistance of the H-fuse.
|
| ||||
| OK | |
| 3.CHECK WIRE HARNESS (BLOWER MOTOR - BODY GROUND) |
![]() |
Disconnect the E60 motor connector.
Measure the resistance of the wire harness side connector.
| Tester Connection | Specified Condition |
| E60-1 (GND) - Body ground | Below 1 Ω |
|
| ||||
| OK | |
| 4.CHECK WIRE HARNESS (BLOWER MOTOR - BATTERY) |
![]() |
Disconnect the E60 motor connector.
Measure the voltage of the wire harness side connector.
| Tester Connection | Condition | Specified Condition |
| E60-3 (+B) - Body ground | Ignition switch on (IG) | 10 to 14 V |
|
| ||||
| OK | |
| 5.CHECK BLOWER W/ FAN MOTOR SUB-ASSEMBLY |
![]() |
Disconnect the E41 amplifier connector.
Connect the E60 motor connector.
Measure the voltage of the connector.
| Tester Connection | Condition | Specified Condition |
| E60-2 (SI) - Body ground | Ignition switch on (IG) | 4.5 to 5.5 V |
|
| ||||
| OK | |
| 6.CHECK WIRE HARNESS (AIR CONDITIONING AMPLIFIER - BODY GROUND) |
![]() |
Disconnect the E41 amplifier connector.
Measure the voltage of the wire harness side connector.
| Tester Connection | Condition | Specified Condition |
| E41-23 (BLW) - Body ground | Ignition switch on (IG) Blower switch OFF | 4.5 to 5.5 V |
|
| ||||
| OK | |
| 7.CHECK AIR CONDITIONING AMPLIFIER |
![]() |
Remove the air conditioning amplifier with its connectors still connected.
Check the waveform of the amplifier connector.
| Item | Content |
| Tester Connection | BLW (E41-23) - GND (E41-14) |
| Tool Setting | 1 V/DIV., 500 μsec./DIV. |
| Condition | Ignition switch on (IG) Blower switch LO |
|
| ||||
| OK | ||
| ||