AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > DATA LIST / ACTIVE TEST |
| DATA LIST |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Data List.
According to the display on the intelligent tester, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Room Temperature Sensor | Room temperature sensor / Min.: -6.5°C (20.3°F) Max.: 57.25°C (135.05°F) | Actual room temperature displayed | Open in the circuit: -6.5°C (20.3°F) Short in the circuit: 57.25°C (135.05°F) |
| Ambient Temp Sensor | Ambient temperature sensor / Min.: -23.3°C (-9.94°F) Max.: 65.95°C (150.71°F) | Actual ambient temperature displayed | Open in the circuit: -23.3°C (-9.94°F) Short in the circuit: 65.95°C (150.71°F) |
| Adjusted Ambient Temp | Adjusted ambient temperature / Min.: -30.8°C (-23.44°F) Max.: 50.8°C (123.44°F) | - | - |
| Evaporator Fin Thermistor | Evaporator temperature sensor / Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) | Actual evaporator temperature displayed | Open in the circuit: -29.7°C (-21.46°F) Short in the circuit: 59.55°C (139.19°F) |
| Solar Sensor (D side) | Driver side solar sensor / Min.: 0, Max.: 255 | Driver side solar sensor value increases as brightness increases | - |
| Solar Sensor (P side) | Passenger side solar sensor / Min.: 0, Max.: 255 | Passenger side solar sensor value increases as brightness increases | - |
| Engine Coolant Temp | Engine coolant temperature / Min.: 1.3°C (34.34°F) Max.: 90.55°C (194.99°F) | Actual engine coolant temperature is displayed after engine warmed up | - |
| Set Temperature (D side) | Driver side set temperature / Min.: 0°C (32°F) Max.: 30°C (54°F) | Driver side actual set temperature is displayed | - |
| Set Temperature (P side) | Passenger side set temperature / Min.: 0°C (32°F) Max.: 30°C (54°F) | Passenger side actual set temperature is displayed | - |
| Blower Motor Speed Level | Blower motor speed level / Min.: 0 level, Max.: 31 level | Increases 0 to 31 as blower motor speed increases | - |
| Regulator Pressure Sensor | Regulator pressure sensor / Min.: -0.45668 MPaG Max.: 3.29437 MPaG | Actual regulator pressure displayed | - |
| Regulator Control Current | Compressor assembly with pulley / Min.: 0 A Max.: 0.997 A | Value changes between 0 A and 0.997 A in accordance with compressor operation | - |
| Air Mix Servo Targ Pulse (D) | Driver side air mix servo motor / Min.: 0, Max.: 255 | LHD: Max. cold: 92 (pulse) Max. hot: 5 (pulse) RHD: Max. cold: 6 (pulse) Max. hot: 93 (pulse) | - |
| Air Mix Servo Targ Pulse (P) | Passenger side air mix servo motor / Min.: 0, Max.: 255 | LHD: Max. cold: 6 (pulse) Max. hot: 93 (pulse) RHD: Max. cold: 92 (pulse) Max. hot: 5 (pulse) | - |
| Air Outlet Servo Pulse (D) | Air outlet damper servo motor / Min.: 0, Max.: 255 | FACE: 47 (pulse) B/L: 37 (pulse) FOOT: 17 (pulse) FOOT/DEF: 9 (pulse) DEF: 5 (pulse) | - |
| Air Inlet Damper Targ Pulse | Air inlet damper servo motor / Min.: 0, Max.: 255 | LHD: RECIRCULATION: 19 (pulse) FRESH: 7 (pulse) RHD: RECIRCULATION: 7 (pulse) FRESH: 25 (pulse) | - |
| Electric Heater Count* | Electric (PTC) heater count / Min.: 0 Max.: 3 | Actual number of the heater elements to be heated is displayed | - |
| Shift Set Temperature | Shift set temperature / 2 C incr, 1 C incr, NORMAL, 1 C decr, 2 C decr | Customized value displayed | - |
| Air Inlet Mode | Air inlet mode / AUTO, MANUAL | Customized value displayed | - |
| Compressor Mode | Compressor mode / AUTO, MANUAL | Customized value displayed | - |
| Compressor/DEF Mode | Compressor / DEF Mode / LINK, NORMAL | Customized value displayed | - |
| Evaporator Control | Evaporator Control / AUTO, MANUAL | Customized value displayed | - |
| Foot/DEF Auto Mode | Foot / DEF auto mode / ON, OFF | Customized value displayed | - |
| Foot/DEF Auto Blow Up | Foot / DEF automatic blow up function / ON, OFF | Customized value displayed | - |
| Ambient Temperature Shift | Ambient temperature shift / 3C incr, 2C incr, 1C incr, Normal, 1C decr, 2C decr, 3C decr | Customized value displayed | - |
| Number of Trouble Codes | Number of trouble codes / Min.: 0, Max.: 255 | Number of DTCs displayed | - |
| ACTIVE TEST |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Active Test.
According to the display on the intelligent tester, perform the Active Test.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Blower Motor | Blower motor | Min.: 0, Max.: 31 | - |
| Defogger Relay (Rear) | Defogger relay (Rear) | ON or OFF | - |
| Electric Heater 1*1,*2 | No. 1 PTC heater relay | ON or OFF | - |
| Electric Heater 2*1,*2 | No. 2 PTC heater relay | ON or OFF | - |
| Electric Heater 3*1,*3 | No. 3 PTC heater relay | ON or OFF | - |
| Air Mix Servo Targ Pulse (D) | Air mix servo motor pulse (D side) | Min.: 0, Max.: 255 | - |
| Air Mix Servo Targ Pulse (P) | Air mix servo motor pulse (P side) | Min.: 0, Max.: 255 | - |
| Air Outlet Servo Pulse (D) | Air outlet servo motor pulse | Min.: 0, Max.: 255 | - |
| Air Inlet Damper Targ Pulse | Air inlet damper target pulse | Min.: 0, Max.: 255 | - |