Home › ENGINE · 2AD-FHV › FUEL › FUEL SUPPLY PUMP

FUEL SUPPLY PUMP > INSPECTION

for Preparation Click here



1. INSPECT FUEL SUPPLY PUMP ASSEMBLY


    A209097E01
  1. Inspect the suction control valve.

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      1 - 2
      20°C (68°F)
      1.9 to 2.3 Ω

      Text in Illustration 
      *1
      Component without harness connected
      (Suction Control Valve)

      HINT:
      The temperature indicated in "Condition" is the temperature of the suction control valve.

      If the result is not as specified, replace the supply pump assembly.



    A209098E01
  1. Inspect the fuel temperature sensor.

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      1 - 2
      20°C (68°F)
      2.32 to 2.59 Ω
      1 - 2
      80°C (176°F)
      0.310 to 0.326 Ω

      Text in Illustration 
      *1
      Component without harness connected
      (Fuel Temperature Sensor)
      If the result is not as specified, replace the supply pump assembly.