COMMON RAIL > INSPECTION |
| 1. INSPECT COMMON RAIL ASSEMBLY |
![]() |
Inspect the fuel pressure sensor.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 5 (PR) - 4 (E2) | Always | 16.4 kΩ or less |
| 2 (PR2) - 3 (E2S) | Always | 16.4 kΩ or less |
| 6 (VC) - 5 (PR) | Always | 3 kΩ or less |
| 1 (VCS) - 2 (PR2) | Always | 3 kΩ or less |
| *1 | Component without harness connected (Fuel Pressure Sensor) |
![]() |
Inspect the pressure discharge valve.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 0.96 to 1.16 Ω |
| *1 | Component without harness connected (Pressure Discharge Valve) |