ELECTRONIC POWER STEERING SYSTEM > EPS Warning Light Circuit |

| 1.CHECK DTC |
Using the intelligent tester, check for DTCs and confirm that there are no problems in the CAN communication system.
|
| ||||
| OK | |
| 2.READ VALUE USING INTELLIGENT TESTER (IG POWER SUPPLY) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and press the intelligent tester main switch ON.
Select the item "IG Power Supply" in the Data List and read the value displayed on the intelligent tester.
| Tester Display | Measurement Item/Range | Normal Condition | Specified Condition |
| IG Power Supply | ECU power source voltage: Min.: 0 V Max.: 20.1531 V | Ignition switch on (IG) | 10 to 14 V |
|
| ||||
| NG | |
| 3.INSPECT FUSE (ECU-IG1) |
Remove the ECU-IG1 fuse from the instrument panel junction block.
Measure the resistance of the fuse.
|
| ||||
| OK | |
| 4.CHECK WIRE HARNESS (POWER STEERING ECU - BATTERY) |
![]() |
Disconnect the A2 and E21 ECU connectors.
Measure the voltage of the wire harness side connectors.
| Tester Connection | Condition | Specified Condition |
| E21-5 (IG) - A2-2 (PGND) | Ignition switch on (IG) | 10 to 14 V |
|
| ||||
| OK | |
| 5.READ VALUE USING TECHSTREAM (PIG POWER SUPPLY) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and press the intelligent tester main switch ON.
Select the item "PIG Power Supply" in the Data List and read the value displayed on the intelligent tester.
| Tester Display | Measurement Item/Range | Normal Condition | Specified Condition |
| PIG Power Supply | PIG power supply: Min.: 0 V Max.: 20.1531 V | Power steering in operation | 10 to 14 V |
|
| ||||
| NG | |
| 6.INSPECT FUSE (EMPS) |
Remove the EMPS fuse from the engine room No. 1 relay block.
Measure the resistance of the fuse.
|
| ||||
| OK | |
| 7.CHECK WIRE HARNESS (POWER STEERING ECU - BATTERY) |
![]() |
Disconnect the A2 ECU connector.
Measure the voltage of the wire harness side connector.
| Tester Connection | Specified Condition |
| A2-1 (PIG) - A2-2 (PGND) | 10 to 14 V |
|
| ||||
| OK | |
| 8.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (METER / GAUGE SYSTEM) |
Perform the Active Test of the combination meter using the intelligent tester.
| Item | Test Details | Diagnostic Note |
| Indicat. EPS | P/S indicator light ON/OFF | - |
Check that the P/S warning light operates in accordance with the Active Test
|
| ||||
| OK | ||
| ||