Home › SECURITIES › ENGINE IMMOBILISER › ENGINE IMMOBILISER SYSTEM (w/ Entry and Start System)

ENGINE IMMOBILISER SYSTEM (w/ Entry and Start System) > Certification ECU Power Source Circuit

for Preparation Click here


DESCRIPTION

This circuit provides power to operate the certification ECU.

WIRING DIAGRAM


B130972E02


INSPECTION PROCEDURE

1.INSPECT FUSE (ECU-B)
  1. Remove the ECU-B fuse from the engine room No. 2 relay block.

  1. Measure the resistance of the fuse.

    Standard resistance:
    Below 1 Ω



NG
REPLACE FUSE
OK


2.CHECK WIRE HARNESS (CERTIFICATION ECU - BATTERY AND BODY GROUND)
B107456E31
  1. Disconnect the E63 ECU connector.

  1. Measure the resistance and voltage of the wire harness side connector.

    Standard resistance:
    Tester Connection
    Specified Condition
    E63-17 (E) - Body ground
    Below 1 Ω

    Standard voltage:
    Tester Connection
    Specified Condition
    E63-1 (+B1) - Body ground
    11 to 14 V



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE