SLIDING ROOF SYSTEM > Sliding Roof ECU Power Source Circuit |

| 1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (SLIDING ROOF OPERATION) |
Select the Active Test, use the intelligent tester to generate a control command, and then check that the sliding roof operates normally.
| Item | Test Details | Diagnostic Note |
| Slide Roof | Operate sliding roof OPEN / DOWN OPEN / DOWN: Sliding roof OPEN / DOWN operation occurs OFF: Sliding roof is not operating | - |
| Slide Roof | Operate sliding roof CLOSE / UP CLOSE / UP: Sliding roof CLOSE / UP operation occurs OFF: Sliding roof is not operating | - |
|
| ||||
| OK | |
| 2.INSPECT FUSE (S/ROOF, ECU-IG1) |
Remove the S/ROOF and ECU-IG1 fuses from the instrument panel junction block.
Measure the resistance of the fuses.
|
| ||||
| OK | |
| 3.CHECK WIRE HARNESS (SLIDING ROOF DRIVE GEAR - BATTERY AND BODY GROUND) |
![]() |
Disconnect the R9 gear connectors.
Measure the voltage and resistance of the wire harness side connectors.
| Tester Connection | Switch Condition | Specified Condition |
| R9-1 (B) - Body ground | Always | 11 to 14 V |
| R9-5 (IG) - Body ground | Ignition switch off | Below 1 V |
| R9-5 (IG) - Body ground | Ignition switch on (IG) | 11 to 14 V |
| Tester Connection | Specified Condition |
| R9-2 (E) - Body ground | Below 1 Ω |
|
| ||||
| OK | ||
| ||