Home › BODY ELECTRICAL › DOOR LOCK › POWER DOOR LOCK CONTROL SYSTEM

POWER DOOR LOCK CONTROL SYSTEM > Only Driver Door LOCK / UNLOCK Functions do not Operate

for Preparation Click here


DESCRIPTION

The main body ECU receives lock / unlock switch signals and activates the door lock motor accordingly.

WIRING DIAGRAM


E114761E03


INSPECTION PROCEDURE

1.READ VALUE USING INTELLIGENT TESTER (LOCK POSITION SWITCH)
  1. Use the Data List to check if the door lock is functioning properly.

    Main body ECU 
    Item
    Measurement Item / Display (Range)
    Normal Condition
    Diagnostic Note
    D-Door Lock Pos SW
    Driver side door lock position switch signal ON / OFF
    ON: Driver side door is unlocked
    OFF: Driver side door is locked
    -

    OK:
    When the door lock is operating, the intelligent tester should display as shown in the table.



OK
REPLACE INSTRUMENT PANEL JUNCTION BLOCK (MAIN BODY ECU)
NG


2.INSPECT FRONT DOOR WITH MOTOR LOCK ASSEMBLY (DRIVER SIDE)


    E123888E01
  1. for LHD:

    1. Apply the battery voltage to the motor terminals and check the operation of the door lock motor.

      OK:
      Measurement Condition
      Specified Condition
      Battery positive (+) → 4 (L)
      Battery negative (-) → 1 (UL)
      Lock
      Battery positive (+) → 1 (UL)
      Battery negative (-) → 4 (L)
      Unlock

    2. Measure the resistance of the position switch.

      Standard resistance:
      Tester Connection
      Switch Condition
      Specified Condition
      8 (LSSR) - 7 (E)
      Lock
      10 kΩ or higher
      8 (LSSR) - 7 (E)
      Unlock
      Below 1 Ω



    E123889E02
  1. for RHD (w/o Double Locking System):

    1. Apply the battery voltage to the motor terminals and check the operation of the door lock motor.

      OK:
      Measurement Condition
      Specified Condition
      Battery positive (+) → 4 (L)
      Battery negative (-) → 1 (UL)
      Lock
      Battery positive (+) → 1 (UL)
      Battery negative (-) → 4 (L)
      Unlock

    2. Measure the resistance of the position switch.

      Standard resistance:
      Tester Connection
      Switch Condition
      Specified Condition
      7 (LSSR) - 8 (E)
      Lock
      10 kΩ or higher
      7 (LSSR) - 8 (E)
      Unlock
      Below 1 Ω



    E123913E03
  1. for RHD (w/ Double Locking System):

    1. Apply the battery voltage to the motor terminals and check the operation of the door lock motor.

      OK:
      Measurement Condition
      Specified Condition
      Battery positive (+) → 2 (L)
      Battery negative (-) → 1 (UL)
      Lock
      Battery positive (+) → 1 (UL)
      Battery negative (-) → 2 (L)
      Unlock

    2. Measure the resistance of the position switch.

      Standard resistance:
      Tester Connection
      Switch Condition
      Specified Condition
      7 (LSSR) - 8 (E)
      Lock
      10 kΩ or higher
      7 (LSSR) - 8 (E)
      Unlock
      Below 1 Ω



NG
REPLACE FRONT DOOR WITH MOTOR LOCK ASSEMBLY (DRIVER SIDE)
OK


3.CHECK WIRE HARNESS (DOOR LOCK - ECU)

E123902E08

  1. for LHD:

    1. Disconnect the H5 door lock connector.

    2. Disconnect the E18 ECU connector.

    3. Disconnect the IH junction block connector.

    4. Measure the resistance of the wire harness side connectors.

      Standard resistance:
      Tester Connection
      Specified Condition
      H5-1 (UL) - IH-9 (ACT-)
      Below 1 Ω
      H5-4 (L) - IH-8 (ACT+)
      Below 1 Ω
      H5-8 (LSSR) - E18-25 (LSWD)
      Below 1 Ω
      H5-7 (E) - Body ground
      Below 1 Ω

  1. for RHD (w/o Double Locking System):

    1. Disconnect the G5 door lock connector.

    2. Disconnect the E18 ECU connector.

    3. Disconnect the IH junction block connector.

    4. Measure the resistance of the wire harness side connectors.

      Standard resistance:
      Tester Connection
      Specified Condition
      G5-1 (UL) - IH-18 (ACT-)
      Below 1 Ω
      G5-4 (L) - IH-17 (ACT+)
      Below 1 Ω
      G5-7 (LSSR) - E18-25 (LSWD)
      Below 1 Ω
      G5-8 (E) - Body ground
      Below 1 Ω

  1. for RHD (w/ Double Locking System):

    1. Disconnect the G5 door lock connector.

    2. Disconnect the E18 ECU connector.

    3. Disconnect the IH junction block connector.

    4. Measure the resistance of the wire harness side connectors.

      Standard resistance:
      Tester Connection
      Specified Condition
      G5-1 (UL) - IH-18 (ACT-)
      Below 1 Ω
      G5-2 (L) - IH-17 (ACT+)
      Below 1 Ω
      G5-7 (LSSR) - E18-25 (LSWD)
      Below 1 Ω
      G5-8 (E) - Body ground
      Below 1 Ω



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK