FRONT DOOR LOCK > INSPECTION |
| 1. INSPECT FRONT DOOR WITH MOTOR LOCK ASSEMBLY (for Driver Side) |
for LHD:
![]() |
Apply the battery voltage to the motor terminals and check the operation of the door lock motor.
| Measurement Condition | Specified Condition |
| Battery positive (+) → 4 (L) Battery negative (-) → 1 (UL) | Lock |
| Battery positive (+) → 1 (UL) Battery negative (-) → 4 (L) | Unlock |
Measure the resistance of the door lock position switch.
| Tester Connection | Switch Condition | Specified Condition |
| 8 (LSSR) - 7 (E) | Lock | 10 kΩ or higher |
| 8 (LSSR) - 7 (E) | Unlock | Below 1 Ω |
![]() |
Measure the resistance of the door key lock and unlock switch operation.
| Tester Connection | Switch Condition | Specified Condition |
| 9 (L) - 7 (E) | Lock | Below 1 Ω |
| 9 (L) - 7 (E) | OFF | 10 kΩ or higher |
| 10 (UL) - 7 (E) | Unlock | Below 1 Ω |
| 10 (UL) - 7 (E) | OFF | 10 kΩ or higher |
![]() |
for RHD (w/o Double Locking System):
Apply the battery voltage to the motor terminals and check the operation of the door lock motor.
| Measurement Condition | Specified Condition |
| Battery positive (+) → 4 (L) Battery negative (-) → 1 (UL) | Lock |
| Battery positive (+) → 1 (UL) Battery negative (-) → 4 (L) | Unlock |
Measure the resistance of the position switch.
| Tester Connection | Switch Condition | Specified Condition |
| 7 (LSSR) - 8 (E) | Lock | 10 kΩ or higher |
| 7 (LSSR) - 8 (E) | Unlock | Below 1 Ω |
![]() |
Measure the resistance of the door lock and unlock switch.
| Measurement Condition | Switch Condition | Specified Condition |
| 5 (UL) -8 (E) | Lock | Below 1 Ω |
| 5 (UL) -8 (E) | OFF | 10 kΩ or higher |
| 6 (L) - 8 (E) | Unlock | Below 1 Ω |
| 6 (L) - 8 (E) | OFF | 10 kΩ or higher |
![]() |
for RHD (w/ Double Locking System):
Apply the battery voltage to the motor terminals and check the operation of the door lock motor.
| Measurement Condition | Specified Condition |
| Battery positive (+) → 2 (L) Battery negative (-) → 1 (UL) | Lock |
| Battery positive (+) → 1 (UL) Battery negative (-) → 2 (L) | Unlock |
Measure the resistance of the position switch.
| Tester Connection | Switch Condition | Specified Condition |
| 7 (LSSR) - 8 (E) | Lock | 10 kΩ or higher |
| 7 (LSSR) - 8 (E) | Unlock | Below 1 Ω |
![]() |
Measure the resistance of the door lock and unlock switch.
| Measurement Condition | Switch Condition | Specified Condition |
| 5 (UL) -8 (E) | Lock | Below 1 Ω |
| 5 (UL) -8 (E) | OFF | 10 kΩ or higher |
| 6 (L) - 8 (E) | Unlock | Below 1 Ω |
| 6 (L) - 8 (E) | OFF | 10 kΩ or higher |
| 2. INSPECT FRONT DOOR WITH MOTOR LOCK ASSEMBLY (for Passenger Side) |
for LHD:
![]() |
Apply the battery voltage to the door lock motor and check the operation of the door lock motor.
| Measurement Condition | Specified Condition |
| Battery positive (+) → 4 (L) Battery negative (-) → 1 (UL) | Lock |
| Battery positive (+) → 1 (UL) Battery negative (-) → 4 (L) | Unlock |
Measure the resistance of the door lock position switch.
| Tester Connection | Switch Condition | Specified Condition |
| 7 (LSSR) - 8 (E) | Lock | 10 kΩ or higher |
| 7 (LSSR) - 8 (E) | Unlock | Below 1 Ω |
![]() |
for RHD (w/o Double Locking System):
Apply the battery voltage to the door lock motor and check the operation of the door lock motor.
| Measurement Condition | Specified Condition |
| Battery positive (+) → 4 (L) Battery negative (-) → 1 (UL) | Lock |
| Battery positive (+) → 1 (UL) Battery negative (-) → 4 (L) | Unlock |
Measure the resistance of the door lock position switch.
| Tester Connection | Switch Condition | Specified Condition |
| 8 (LSSR) - 7 (E) | Lock | 10 kΩ or higher |
| 8 (LSSR) - 7 (E) | Unlock | Below 1 Ω |
![]() |
for RHD (w/ Double Locking System):
Apply the battery voltage to the door lock motor and check the operation of the door lock motor.
| Measurement Condition | Specified Condition |
| Battery positive (+) → 4 (L) Battery negative (-) → 3 (UL) | Lock |
| Battery positive (+) → 3 (UL) Battery negative (-) → 4 (L) | Unlock |
Measure the resistance of the door lock position switch.
| Tester Connection | Switch Condition | Specified Condition |
| 8 (LSSR) - 7 (E) | Lock | 10 kΩ or higher |
| 8 (LSSR) - 7 (E) | Unlock | Below 1 Ω |