METER / GAUGE SYSTEM > FAIL-SAFE CHART |
| Condition | Response | Recovery |
| Speed data is interrupted for 0.12 seconds | Gauge needle indicates below 0 km/h (0 mph) | Normal data is received |
| Condition | Response | Recovery |
| Tachometer data is interrupted for 0.12 seconds | Gauge needle indicates below 0 rpm | Normal data is received |
| Condition | Response | Recovery |
| Water temperature data is interrupted for 3.1 seconds | Gauge needle indicates below "C" | Normal data is received |
| Condition | Response | Recovery |
| "P" to "D" data is interrupted for 3 seconds | All shift indicators go off | Normal data is received |
| Condition | Response | Recovery |
| Variable resistance malfunction | Light control output 100% | Normal data is received |
| Condition | Response | Recovery |
| Regular data is interrupted for 0.12 seconds | Calculation stops | Normal data is received |