Home › BODY ELECTRICAL › METER › METER / GAUGE SYSTEM

METER / GAUGE SYSTEM > Entire Combination Meter does not Operate

for Preparation Click here


DESCRIPTION

This circuit provides power to the combination meter assembly.

WIRING DIAGRAM


E124223E05


INSPECTION PROCEDURE

1.INSPECT FUSE (GAUGE2, ECU-B, IG2)
  1. Remove the GAUGE2 fuse from the instrument panel junction block.

  1. Remove the ECU-B fuse from the No. 2 relay block.

  1. Remove the IG2 fuse from the No. 1 relay block.

  1. Measure the resistance of the fuses.

    Standard resistance:
    Below 1 Ω



NG
REPLACE FUSE
OK


2.INSPECT IG2 RELAY


    B060778E04
  1. Remove the IG2 relay from the No. 1 relay block.

  1. Measure the resistance of the relay.

    Standard resistance:
    Tester Connection
    Specified Condition
    3 - 5
    10 kΩ or higher
    3 - 5
    Below 1 Ω
    (when battery voltage is applied to terminals 1 and 2)



NG
REPLACE IG2 RELAY
OK


3.CHECK WIRE HARNESS (COMBINATION METER - BATTERY AND BODY GROUND)


    E118419E06
  1. Disconnect the E22 meter connector.

  1. Measure the voltage of the wire harness side connector.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    E22-22 (B) - Body ground
    Always
    11 to 14 V
    E22-21 (IG+) - Body ground
    Ignition switch on (IG)
    11 to 14 V

  1. Measure the resistance of the wire harness side connector.

    Standard resistance:
    Tester Connection
    Specified Condition
    E22-33 (ET) - Body ground
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

REPLACE COMBINATION METER ASSEMBLY