Home › TRANSMISSION · U660F AUTOMATIC TRANSAXLE › AUTOMATIC TRANSAXLE SYSTEM

AUTOMATIC TRANSAXLE SYSTEM > ECU Power Source Circuit

for Preparation Click here


DESCRIPTION

When the ignition switch is turned ON, voltage from the MREL terminal of the ECM is applied to the EFI MAIN relay. This causes the contacts of the EFI MAIN relay to close, which supplies power to terminal +B of the TCM.

WIRING DIAGRAM

Refer to DTC U0100 .

INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

1.CHECK TCM (TCM - BODY GROUND)


    C205632E12
  1. Disconnect the TCM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    B128-8 (E1) - Body ground
    Always
    Below 1 Ω

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to TCM)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


2.CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - TCM)


    C209021E01
  1. Remove the integration relay from the engine room No. 1 relay block.

  1. Disconnect the TCM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1A-4 - B128-18 (+B)
    Always
    Below 1 Ω
    1A-4 or B128-18 (+B) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Integration Relay)
    *2
    Front view of wire harness connector
    (to TCM)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

GO TO ECD SYSTEM (ECM POWER SOURCE CIRCUIT) (Click here)