Home › HEATER & AIR CONDITIONING SYSTEM › HEATER › COMBUSTION TYPE POWER HEATER SYSTEM

COMBUSTION TYPE POWER HEATER SYSTEM > Power Heater Alternator Circuit

for Preparation Click here


DESCRIPTION

The ECU receives engine operation signals from the L terminal of the generator assembly. If this circuit is open or shorted, the ECU may incorrectly determine whether the engine is running or stopped. As a result, the heater assembly may not operate properly.

WIRING DIAGRAM


E183957E03


INSPECTION PROCEDURE

1.CHECK HARNESS AND CONNECTOR (HEATER ASSEMBLY - GENERATOR ASSEMBLY)


    E185689E02
  1. Disconnect the A31 heater connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    A31-8 (+) - Body ground
    Engine running
    (Generator operating)
    11 to 14 V

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Heater Assembly)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


2.CHECK HARNESS AND CONNECTOR (HEATER ASSEMBLY - GENERATOR ASSEMBLY)


    E181481E03
  1. Disconnect the A31 heater connector.

  1. Disconnect the B21 generator connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A31-8 (+) - B21-4 (L)
    Always
    Below 1 Ω
    A31-8 (+) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Heater Assembly)
    *2
    Front view of wire harness connector
    (to Generator Assembly)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)