Home › BODY ELECTRICAL › LIGHTING › STOP LIGHT CONTROL RELAY

STOP LIGHT CONTROL RELAY > INSPECTION

for Preparation Click here



1. INSPECT STOP LIGHT CONTROL RELAY ASSEMBLY


    E142629E20
  1. Disconnect the A43 stop light control relay connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    A43-2 (STP) - Body ground
    Brake pedal released
    Below 1 V
    Brake pedal depressed
    11 to 14 V
    A43-6 (+B) - Body ground
    Always
    11 to 14 V

    If the result is not as specified, repair or replace the wire harness or connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A43-4 (GND) - Body ground
    Always
    Below 1 Ω

    If the result is not as specified, repair or replace the wire harness or connector.

  1. Reconnect the A43 stop light control relay connector.



    E150985E19
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    A43-8 (OUT) - Body ground
    Brake pedal released
    Below 1 V
    Brake pedal depressed
    11 to 14 V

    If the result is not as specified, replace the stop light control relay.