Home › BODY ELECTRICAL › LIGHTING › STOP LIGHT SWITCH

STOP LIGHT SWITCH > INSPECTION

for Preparation Click here



1. INSPECT STOP LIGHT SWITCH ASSEMBLY (w/o Stop Light Control Relay)


    B113724E06
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    1 - 2
    Pin pushed
    10 kΩ higher
    Pin released
    Below 1 Ω
    3 - 4
    Pin pushed
    Below 1 Ω
    Pin released
    10 kΩ higher

    If the result is not as specified, there may be a malfunction in the stop light switch.



2. INSPECT STOP LIGHT SWITCH ASSEMBLY (w/ Stop Light Control Relay)


    E164228E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    1 - 2
    Pin pushed
    10 kΩ higher
    Pin released
    Below 1 Ω
    3 - 4
    Pin pushed
    Below 1 Ω
    Pin released
    10 kΩ higher

    If the result is not as specified, there may be a malfunction in the stop light switch.